Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
4590120-03 | 3 - Design Control Reference | 9 - No Longer Used | AMPEX SYSTEMS CORP | 92739 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6105 | 001563889 | A271A0 | 00530 | X | K | A | N | A | 9 Feb 1970 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 9 | 1 | CX | D | 4590120-03 | 92739 |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 96 | 0 | 1 Jan 1996 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CX | 593 | Z | 9 | A | H | Z | W | 062120 | Z | 34760 | GENERATORS-MOTORS-PARTS-NOI |
Defense Supply Center Richmond, Richmond, VA 23297-5000
Motors and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Unclassified
1
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
No QUP
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Department of the Army
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AKPS | Duty Cycle | CONTINUOUS |
CWGQ | Connection Type And Voltage Rating In Volts | 117.0 LINE TO NEUTRAL SINGLE INPUT |
BFMF | Cooling Method | SELF-VENTILATED |
CBBL | Features Provided | HORIZONTAL MOUNTING POSITION AND VERTICAL MOUNTING POSITION |
AGRB | Flat Depth | 0.188 INCHES NOMINAL FIRST END |
ABXQ | Flatted Portion Length | 1.220 INCHES NOMINAL FIRST END |
FREQ | Frequency In Hertz | 60.0 INPUT |
CWFQ | Mounting Facility Circle Diameter | 3.438 INCHES |
AXHR | Mounting Facility Type And Quantity | 4 THREADED HOLE |
AXGY | Mounting Method | FACE |
AAJU | Overall Length | 8.650 INCHES |
ANPZ | Inclosure Feature | OPEN PROTECTED |
BKPQ | Inclosure Specification | COMMERCIAL |
CWCS | Length Of Shaft From Housing | 1.810 INCHES SECOND END |
CWCS | Length Of Shaft From Housing | 1.750 INCHES FIRST END |
CWFX | Rotor Speed Rating In Rpm | 600.0 FIRST MULTIPLE FULL LOAD OR 1200.0 SECOND MULTIPLE FULL LOAD |
ABWV | Shaft Diameter | 0.313 INCHES NOMINAL FIRST END |
ABWV | Shaft Diameter | 0.380 INCHES NOMINAL SECOND END |
CWHZ | Shaft End Characteristic | A12 SINGLE STYLE SECOND END |
CWHZ | Shaft End Characteristic | A5 SINGLE STYLE FIRST END |
AKCT | Shaft Rotation Direction | CLOCKWISE FIRST END |
AKCT | Shaft Rotation Direction | COUNTERCLOCKWISE SECOND END |
AAJT | Overall Height | 4.410 INCHES |
AAJV | Overall Width | 4.410 INCHES |
FAAZ | Phase | SINGLE INPUT |
AXCP | Winding Type | INDUCTION-PERMANENT SPLIT CAPACITOR SPLIT PHASE |
ABGH | Step Diameter | 0.288 INCHES MINIMUM SECOND END AND 0.290 INCHES MAXIMUM SECOND END |
ABGJ | Step Length | 1.260 INCHES NOMINAL SECOND END |
CWDY | Temp Rating | 65.0 AMBIENT DEG CELSIUS |
TTQY | Terminal Type And Quantity | 4 WIRE LEAD |
BKPH | Torque Rating And Type | 4.0 INCH-OUNCES RUNNING AND 4.0 INCH-OUNCES RUNNING |