Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
S1171090A | 3 - Design Control Reference | 2 - Production Item | WESTINGHOUSE ELECTRIC CORP | 79500 | |
S1171090A | 3 - Design Control Reference | 9 - No Longer Used | WESTINGHOUSE ELECTRIC CORP | 11660 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6105 | 002415170 | A271A0 | 16350 | X | 4 | 9 | A | N | A | 0 | 1 Jan 1963 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZR01 | 1 Jul 1997 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | CX | 0 | 1 | CX | 0 | 3 Sep 1978 | 6105000714646 | 27 Aug 1978 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Q | 590 | Z | 9 | A | H | Z | W | 062120 | Z | 34760 | GENERATORS-MOTORS-PARTS-NOI | 1 |
70
Generators and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
NAVY: Medium Demand Velocity Items (Consumables)
Department of the Navy
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AKPS | Duty Cycle | CONTINUOUS |
CWGQ | Connection Type And Voltage Rating In Volts | 230.0 LINE TO NEUTRAL SINGLE INPUT |
BFMF | Cooling Method | AMBIENT AIR |
BKPB | Current Rating Method | LOAD |
CWGL | Current Rating In Amps | 0.320 SINGLE INPUT |
CBBL | Features Provided | VERTICAL MOUNTING POSITION |
AXHR | Mounting Facility Type And Quantity | 4 SLOT |
AXGY | Mounting Method | ADJUSTABLE BASE |
CWDT | Nominal Center To Center Distance Between Mounting Facilities Parallel To Length | 3.000 INCHES |
CWFY | Nominal Center To Center Distance Between Mounting Facilities Parallel To Width | 4.875 INCHES |
AAJU | Overall Length | 9.875 INCHES |
ANPZ | Inclosure Feature | DRIPPROOF-15 DEG |
BKPQ | Inclosure Specification | COMMERCIAL |
CWCS | Length Of Shaft From Housing | 1.500 INCHES SINGLE END |
CNXS | Power Rating | 0.0500 HORSEPOWER OUTPUT |
CWFX | Rotor Speed Rating In Rpm | 1140.0 SINGLE FULL LOAD |
CWDM | Shaft Center To Mounting Surface Distance | 3.500 INCHES SINGLE END |
ABWV | Shaft Diameter | 0.5000 INCHES NOMINAL SINGLE END |
CWHZ | Shaft End Characteristic | A5 SINGLE STYLE SINGLE END |
AKCT | Shaft Rotation Direction | CLOCKWISE SINGLE END OR COUNTERCLOCKWISE SINGLE END |
AAJT | Overall Height | 9.281 INCHES |
AAJV | Overall Width | 6.719 INCHES |
AXCP | Winding Type | SHUNT WOUND |
CWDY | Temp Rating | 50.0 AMBIENT DEG CELSIUS |