| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 34131 | 3 - Design Control Reference | 9 - No Longer Used | LOUIS ALLIS CO THE | 01425 |    | 
| 708198 | 5 - Replaced / Discontinued | 9 - No Longer Used | LOUIS ALLIS CO THE | 01425 |    | 
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 61 | 6105 | 002436596 | A271A0 | 16350 | X | M | 9 | A | N | A | 1 Jan 1963 | 
 Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZW01 | 1 Nov 1998 | |||||||||||||||||||||||||||||
| N9BG | N9GD | 5 | H | Z | HD | HD | 1 Feb 2005 | |||||||||||||||||||||||
Acquire only from the prime contractor although the engineering data identifies the Commercial and Government Entity Code (CAGE) and part number of a source other than the prime contractor. The DoD activity assigning this code shall furnish the name and CAGE Code of the prime contractor to the activity responsible for acquiring the part.
The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date | 
|---|---|---|---|---|---|---|---|---|
| C | CX | 0 | 24 Mar 1970 | 
An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 593 | Z | 9 | A | H | Z | W | 062120 | Z | 34760 | GENERATORS-MOTORS-PARTS-NOI | 
Motors and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Department of the Navy 
Defense Logistics Agency 
| MRC | Decoded Requirement | Clear Text Reply | 
|---|---|---|
| AKPS | Duty Cycle | CONTINUOUS | 
| CWGQ | Connection Type And Voltage Rating In Volts | 220.0 LINE TO NEUTRAL SINGLE INPUT | 
| CWGL | Current Rating In Amps | 6.950 SINGLE INPUT | 
| BKPB | Current Rating Method | LOAD | 
| CBBL | Features Provided | VERTICAL MOUNTING POSITION AND HORIZONTAL MOUNTING POSITION | 
| AXHR | Mounting Facility Type And Quantity | 4 UNTHREADED HOLE | 
| AXGY | Mounting Method | FIXED BASE | 
| CWDT | Nominal Center To Center Distance Between Mounting Facilities Parallel To Length | 6.500 INCHES | 
| CWFY | Nominal Center To Center Distance Between Mounting Facilities Parallel To Width | 8.000 INCHES | 
| AAJU | Overall Length | 21.812 INCHES | 
| ANPZ | Inclosure Feature | SPLASH PROOF | 
| BKPQ | Inclosure Specification | COMMERCIAL | 
| CWCS | Length Of Shaft From Housing | 5.250 INCHES SINGLE END | 
| CNXS | Power Rating | 1.5000 HORSEPOWER OUTPUT | 
| CWFX | Rotor Speed Rating In Rpm | 3500.0 SINGLE FULL LOAD | 
| CWDM | Shaft Center To Mounting Surface Distance | 5.000 INCHES SINGLE END | 
| ABWV | Shaft Diameter | 1.0000 INCHES NOMINAL SINGLE END | 
| CWHZ | Shaft End Characteristic | A9 FIRST STYLE SINGLE END AND A2 SECOND STYLE SINGLE END AND A12 THIRD STYLE SINGLE END | 
| AKCT | Shaft Rotation Direction | CLOCKWISE SINGLE END OR COUNTERCLOCKWISE SINGLE END | 
| AAJT | Overall Height | 14.375 INCHES | 
| AAJV | Overall Width | 9.844 INCHES | 
| AXCP | Winding Type | COMPOUND WOUND | 
| ABGH | Step Diameter | 0.9690 INCHES NOMINAL SINGLE END | 
| CWDY | Temp Rating | 50.0 AMBIENT DEG CELSIUS AND 40.0 OPERATING DEG CELSIUS | 
| AASA | Thread Length | 0.8120 INCHES NOMINAL SINGLE END |