Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
404957-1 | 3 - Design Control Reference | 2 - Production Item | RAYTHEON COMPANY | 82577 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6105 | 003035995 | A271A0 | 19258 | X | M | 9 | A | N | U | 1 Jan 1963 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZU01 | 1 Apr 1991 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | CX | 0 | 15 Dec 1974 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Q | 593 | Z | 9 | A | H | Z | W | 062120 | Z | 34760 | GENERATORS-MOTORS-PARTS-NOI | 1 |
70
Motors and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CWGQ | Connection Type And Voltage Rating In Volts | 115.0 LINE TO NEUTRAL SINGLE INPUT |
BFMK | Control Field Impedance Rating In Ohms | 495.0 |
BKPS | Control Field Voltage Type And Rating In Volts | 115.0 AC |
BFML | Control Field Winding Type | SINGLE WINDING W/CENTER TAP |
ACDC | Current Type | AC INPUT |
FREQ | Frequency In Hertz | 400.0 INPUT |
AKAE | Maximum Operating Altitude Rating | 50000.0 FEET |
CWFQ | Mounting Facility Circle Diameter | 1.250 INCHES |
AXHR | Mounting Facility Type And Quantity | 4 THREADED HOLE |
AAJU | Overall Length | 3.120 INCHES |
ANPZ | Inclosure Feature | TOTALLY INCLOSED |
BKPQ | Inclosure Specification | COMMERCIAL |
CWCS | Length Of Shaft From Housing | 0.918 INCHES SINGLE END |
CWFX | Rotor Speed Rating In Rpm | 9500.0 SINGLE NO LOAD |
CWHZ | Shaft End Characteristic | A23 SINGLE STYLE SINGLE END |
ABWV | Shaft Diameter | 0.2282 INCHES MINIMUM SINGLE END AND 0.2292 INCHES MAXIMUM SINGLE END |
AAJV | Overall Width | 1.755 INCHES |
FAAZ | Phase | SINGLE INPUT |
FEAT | Special Features | PANEL MTG |
CWDY | Temp Rating | 22.0 OPERATING DEG CELSIUS |
BKPH | Torque Rating And Type | 2.7 INCH-OUNCES STALLED |