6105-00-539-9841

MOTOR,DIRECT CURRENT


6105-00-539-9841 (6105005399841, 005399841)
Part Number (1 listing): 96A395
Summary

FSG 61 / FSC 6105

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1963

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6105-00-539-9841 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
96A3953 - Design Control Reference2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6105-00-539-9841 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616105005399841A271A016350XM9ANA01 Jan 1963
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6105

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Motors, Electrical

005399841

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6105-00-539-9841

A271A0

Federal Item Identification Guide (FIIG_4065)

16350

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6105-00-539-9841 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
Code Definitions

FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6105-00-539-9841 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
CCX024 Mar 1970
Code Definitions

C

Item Standardization Code (ISC_2650)


An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

24 Mar 1970

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6105-00-539-9841 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Q590Z9AHZW062120Z34760GENERATORS-MOTORS-PARTS-NOI1
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Q

Less Than Carload (LCL_CD_2760)


70

590

Water Commodity Code (WRT_CMDTY_CD_9275)


Generators and Parts, (machinery and parts), (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

062120

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34760

Uniform Freight Classification (UFC_CD_MODF_3040)

GENERATORS-MOTORS-PARTS-NOI

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6105-00-539-9841 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKPSDuty CycleCONTINUOUS
CWGQConnection Type And Voltage Rating In Volts115.0 LINE TO NEUTRAL SINGLE INPUT
BFMFCooling MethodNATURAL CONVECTION VENTILATED
BKPBCurrent Rating MethodLOAD
CBBLFeatures ProvidedVERTICAL MOUNTING POSITION
AXHRMounting Facility Type And Quantity4 UNTHREADED HOLE
AXGYMounting MethodFIXED BASE
CWDTNominal Center To Center Distance Between Mounting Facilities Parallel To Length10.500 INCHES
CWFYNominal Center To Center Distance Between Mounting Facilities Parallel To Width12.500 INCHES
AAJUOverall Length30.063 INCHES
BKPQInclosure SpecificationCOMMERCIAL
ANPZInclosure FeatureOPEN
CWCSLength Of Shaft From Housing4.625 INCHES SINGLE END
ABWVShaft Diameter1.6250 INCHES NOMINAL SINGLE END
CWHZShaft End CharacteristicA9 SINGLE STYLE SINGLE END
CWDMShaft Center To Mounting Surface Distance8.000 INCHES SINGLE END
AKCTShaft Rotation DirectionCOUNTERCLOCKWISE SINGLE END
AAJTOverall Height21.938 INCHES
AAJVOverall Width15.750 INCHES
AXCPWinding TypeSHUNT WOUND W/COMMUTATING POLES
CWDYTemp Rating50.0 AMBIENT DEG CELSIUS AND 40.0 OPERATING DEG CELSIUS
TTQYTerminal Type And Quantity6 SOLDER LUG


Back to Top
Back to Top