Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
U203330-19-2-3 | 3 - Design Control Reference | 2 - Production Item | TRANSICOIL LLC | 82686 | ![]() |
U202916-19-2-3 | 5 - Replaced / Discontinued | 2 - Production Item | TRANSICOIL LLC | 82686 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6105 | 005560477 | A271A0 | 19258 | X | K | A | N | U | 1 Jan 1961 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZU01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 2005 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | CX | 0 | 15 Nov 1965 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
593 | Z | 9 | A | H | Z | W | 062120 | Z | 34760 | GENERATORS-MOTORS-PARTS-NOI |
Motors and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CWGQ | Connection Type And Voltage Rating In Volts | 52.0 LINE TO NEUTRAL SINGLE INPUT |
BFMF | Cooling Method | NONVENTILATED |
BFMJ | Control Field Current Rating In Amps | 0.085 |
BFML | Control Field Winding Type | SINGLE WINDING |
BKPS | Control Field Voltage Type And Rating In Volts | 52.0 AC |
BKPB | Current Rating Method | NO LOAD |
CWGL | Current Rating In Amps | 0.085 SINGLE INPUT |
ACDC | Current Type | AC INPUT |
CBBL | Features Provided | HORIZONTAL MOUNTING POSITION AND VERTICAL MOUNTING POSITION |
FREQ | Frequency In Hertz | 400.0 INPUT |
AKAE | Maximum Operating Altitude Rating | 50000.0 FEET |
AXHR | Mounting Facility Type And Quantity | 1 CLAMP COLLAR |
AXGY | Mounting Method | CLAMP RING |
AAJU | Overall Length | 1.450 INCHES |
BKPQ | Inclosure Specification | COMMERCIAL |
ANPZ | Inclosure Feature | TOTALLY INCLOSED |
CWCS | Length Of Shaft From Housing | 0.136 INCHES SINGLE END |
CWFX | Rotor Speed Rating In Rpm | 10000.0 SINGLE NO LOAD |
CWHZ | Shaft End Characteristic | A14 SINGLE STYLE SINGLE END |
ABWV | Shaft Diameter | 0.1247 INCHES NOMINAL SINGLE END |
AAJT | Overall Height | 0.900 INCHES |
AAJV | Overall Width | 0.900 INCHES |
FAAZ | Phase | SINGLE INPUT |
BKPH | Torque Rating And Type | 0.25 INCH-OUNCES STALLED |
AXFH | Spline Length | 0.0900 INCHES NOMINAL SINGLE END |
AAUH | Spline Minor Diameter | 0.1000 INCHES NOMINAL SINGLE END |
ABSA | Spline Quantity | 12 SINGLE END |
CWDY | Temp Rating | 60.0 AMBIENT DEG CELSIUS AND -55.0 OPERATING DEG CELSIUS AND 71.0 OPERATING DEG CELSIUS |
TTQY | Terminal Type And Quantity | 4 WIRE LEAD |