Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
498722-401 | 3 - Design Control Reference | 2 - Production Item | SPD ELECTRICAL SYSTEMS, INC | 30086 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6105 | 007257994 | A271A0 | 00530 | X | K | B | N | U | 1 Jan 1963 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZU01 | 1 Apr 1991 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | CX | 0 | 18 Jun 1970 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Q | 593 | Z | 9 | A | H | Z | W | 062120 | Z | 34760 | GENERATORS-MOTORS-PARTS-NOI | 1 |
70
Motors and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AKPS | Duty Cycle | CONTINUOUS |
CWGQ | Connection Type And Voltage Rating In Volts | 120.0 LINE TO NEUTRAL SINGLE INPUT |
BFMF | Cooling Method | NONVENTILATED |
CWGL | Current Rating In Amps | 70.000 SINGLE INPUT |
BKPB | Current Rating Method | LOAD |
CNMM | Frame Size Designation | 182D |
FREQ | Frequency In Hertz | 60.0 INPUT |
CWFQ | Mounting Facility Circle Diameter | 10.000 INCHES |
AXHR | Mounting Facility Type And Quantity | 4 UNTHREADED HOLE |
AXGY | Mounting Method | FLANGE |
AAJU | Overall Length | 16.062 INCHES |
ANPZ | Inclosure Feature | WATERTIGHT |
BKPQ | Inclosure Specification | NEMA |
CWCS | Length Of Shaft From Housing | 4.750 INCHES SINGLE END |
CNXS | Power Rating | 1.0000 HORSEPOWER OUTPUT |
CWFX | Rotor Speed Rating In Rpm | 1725.0 SINGLE FULL LOAD |
ABWV | Shaft Diameter | 0.8750 INCHES NOMINAL SINGLE END |
CWHZ | Shaft End Characteristic | A12 SINGLE STYLE SINGLE END |
AKCT | Shaft Rotation Direction | COUNTERCLOCKWISE SINGLE END |
AAJT | Overall Height | 13.375 INCHES |
AAJV | Overall Width | 10.875 INCHES |
FAAZ | Phase | SINGLE INPUT |
AXCP | Winding Type | INDUCTION-SQUIRREL CAGE |
ABGH | Step Diameter | 0.7460 INCHES NOMINAL SINGLE END |
ABGJ | Step Length | 2.2200 INCHES NOMINAL SINGLE END |
CWDY | Temp Rating | -54.0 OPERATING DEG CELSIUS AND 54.0 OPERATING DEG CELSIUS AND 50.0 AMBIENT DEG CELSIUS |
TTQY | Terminal Type And Quantity | 1 RECEPTACLE |