Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
SJ3HKT9-2 | 3 - Design Control Reference | 2 - Production Item | EASTERN AIR DEVICES INC | 19070 | |
SJ3HKT9-2 | 3 - Design Control Reference | 9 - No Longer Used | EASTERN AIR DEVICES INC | 19070 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6105 | 007637967 | A271A0 | 28454 | X | M | 6 | A | N | C | 1 Jan 1960 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item contains combination of two or more precious metals (silver, gold, platinum).
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
1 | CX | 6 | 3 | CX | 1 | 31 Aug 1984 | 6105000875591 | 3 Sep 1984 |
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
593 | Z | Z | A | H | Z | P | 062120 | A | 34760 | GENERATORS-MOTORS-PARTS-NOI-SUB1 |
Motors and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required. Heavy Lift (HL). Five short tons (10,000 lbs) or more. Applies to any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN). Outsized Dimensions. Dimensions of any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN, CONEXs, and POVs) which exceed six (6) feet in any dimension.
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
BFLQ | Calibration Speed In Rpm | 1000.0 |
BKPC | Calibration Voltage Output Type In Volts | 3.2 AC |
CWGQ | Connection Type And Voltage Rating In Volts | 115.0 LINE TO NEUTRAL SINGLE INPUT |
BKPS | Control Field Voltage Type And Rating In Volts | 20.0 AC |
ACDC | Current Type | AC INPUT |
FREQ | Frequency In Hertz | 400.0 OUTPUT |
AKAE | Maximum Operating Altitude Rating | 60000.0 FEET |
AXHR | Mounting Facility Type And Quantity | 1 CLAMP COLLAR |
AXGY | Mounting Method | END BELL |
AAJU | Overall Length | 3.920 INCHES |
ANPZ | Inclosure Feature | TOTALLY INCLOSED |
CWFX | Rotor Speed Rating In Rpm | 9000.0 SINGLE NO LOAD |
ABWV | Shaft Diameter | 0.1760 INCHES NOMINAL SINGLE END |
CWHZ | Shaft End Characteristic | A14 SINGLE STYLE SINGLE END |
AAJV | Overall Width | 1.750 INCHES |
FAAZ | Phase | SINGLE INPUT |
BKPH | Torque Rating And Type | 2.5 INCH-OUNCES STALLED |
CWDY | Temp Rating | -55.0 OPERATING DEG CELSIUS AND 125.0 OPERATING DEG CELSIUS |