Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
CR10342503 | 3 - Design Control Reference | 2 - Production Item | KEARFOTT CORPORATION | 88818 | ![]() |
CR10342503 | 3 - Design Control Reference | 2 - Production Item | KEARFOTT CORPORATION | 88818 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6105 | 009992167 | A271A0 | 28454 | X | K | Q | N | U | 14 Jan 1966 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
CCLI — Commerce Control List Item Demilitarization not required. CCLI are dual-use (military, commercial, and other strategic uses) items under the jurisdiction of the Bureau of Export Administration, U.S. Department of Commerce, through the Export Administration Regulations. The types of items under the Commerce Control List (CCL) are commodities (i.e., equipment, materials, electronics, propulsion systems, etc.), software, and technology. The CCL does not include those items exclusively controlled by another department or agency of the U.S. Government.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 2 | 2 | SE | D | CR10342503 | 88818 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | CX | 6 | 7 Feb 1985 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SE | 593 | Z | 9 | A | H | Z | W | 062120 | Z | 34760 | GENERATORS-MOTORS-PARTS-NOI |
San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000
Motors and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
A | P | ZZ | Z | 0.3 lbs | 0.050 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
ZZ | ZZ | ZZ | Z | ZZ | ZZ |
Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats
Primary Inventory Control Activity (PICA)
See J.4.1.b
Special Requirements - See specific instructions or drawings provided.
Special requirement – See specific instructions or drawings provided
Special requirements – see specific instructions or drawings provided
Special requirements. See specific instructions or drawings provided.
Special requirements-See specific instructions or drawings provided
Special requirement – See specific instructions or drawings provided.
Special requirement – See specific instructions or drawings provided.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
BFLQ | Calibration Speed In Rpm | 1000.0 |
BKPC | Calibration Voltage Output Type In Volts | 0.5 AC |
CWGQ | Connection Type And Voltage Rating In Volts | 115.0 LINE TO NEUTRAL SINGLE INPUT |
BFMF | Cooling Method | AMBIENT AIR |
BKPS | Control Field Voltage Type And Rating In Volts | 40.0 AC |
ACDC | Current Type | AC INPUT |
AYHE | Excitor Type | SEPARATELY EXCITED |
CBBL | Features Provided | HORIZONTAL MOUNTING POSITION AND VERTICAL MOUNTING POSITION |
FREQ | Frequency In Hertz | 400.0 OUTPUT |
CWFQ | Mounting Facility Circle Diameter | 0.812 INCHES |
AXHR | Mounting Facility Type And Quantity | 4 THREADED HOLE |
AXGY | Mounting Method | FACE |
AAJU | Overall Length | 3.962 INCHES |
BKPQ | Inclosure Specification | COMMERCIAL |
ANPZ | Inclosure Feature | TOTALLY INCLOSED |
CWCS | Length Of Shaft From Housing | 0.376 INCHES SINGLE END |
CNXS | Power Rating | 4.950 WATTS INPUT |
CWFX | Rotor Speed Rating In Rpm | 269.0 SINGLE NO LOAD |
CWHZ | Shaft End Characteristic | A1 SINGLE STYLE SINGLE END |
ABWV | Shaft Diameter | 0.1250 INCHES NOMINAL SINGLE END |
AAJT | Overall Height | 1.062 INCHES |
AAJV | Overall Width | 1.062 INCHES |
FAAZ | Phase | SINGLE INPUT |
BKPH | Torque Rating And Type | 9.0 INCH-OUNCES STALLED |
CWDY | Temp Rating | -54.0 OPERATING DEG CELSIUS AND 125.0 OPERATING DEG CELSIUS |
TTQY | Terminal Type And Quantity | 8 WIRE LEAD |