Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
701527-68 | 3 - Design Control Reference | 2 - Production Item | COLTEC INDUSTRIES INC | 82796 | ![]() |
P18G1007 | 5 - Replaced / Discontinued | 9 - No Longer Used | RELIANCE ELECTRIC | 50380 | ![]() |
P18G1007 | C - Advisory Reference | 1 - Incomplete Part Number | RELIANCE ELECTRIC COMPANY | 71956 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6105 | 010479665 | A271A0 | 00530 | X | K | A | N | A | 16 Sep 1977 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C056 | C165 | 0 | 0 | 1 Jun 2010 |
Not Established
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
C | 1 | 6 | ZZ | 9F | P18G1007 | 71956 | ![]() |
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
USA
CAGE Status Change
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | CX | 0 | 14 Aug 1982 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No Variation. NMFC and UFCC Match.
Commanding Officer, USCG Surface Force Logistics Center, Code 028, Mil Stop 25, 2401 Hawkins Point Road, Baltimore, MD 21226-5000
INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Unclassified
1
ARMY: Item requires special handling or condemnation procedures for specific reasons, such as precious metal content, high dollar value, critical material, or hazardous materiel. Refer to appropriate manuals or directives for specific instructions; MARINE CORPS: Item requires special handling/or condemnation procedures because of specific reasons (i.e., precious metal content, high dollar value, critical material, or hazardous material). Refer to appropriate manuals/directives for specific instructions; NAVY: Field Activity Control Items
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
U.S. Coast Guard
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AKPS | Duty Cycle | CONTINUOUS |
CWGQ | Connection Type And Voltage Rating In Volts | 220.0 LINE TO LINE LOW INPUT OR 440.0 LINE TO LINE HIGH INPUT |
BFMF | Cooling Method | AMBIENT AIR |
CWGL | Current Rating In Amps | 7.350 HIGH INPUT |
BKPB | Current Rating Method | LOAD |
CBBL | Features Provided | HORIZONTAL MOUNTING POSITION |
FREQ | Frequency In Hertz | 60.0 INPUT |
AXHR | Mounting Facility Type And Quantity | 4 UNTHREADED HOLE |
AXGY | Mounting Method | FIXED BASE |
CWDT | Nominal Center To Center Distance Between Mounting Facilities Parallel To Length | 5.500 INCHES |
CWFY | Nominal Center To Center Distance Between Mounting Facilities Parallel To Width | 7.500 INCHES |
AAJU | Overall Length | 13.560 INCHES |
BKPQ | Inclosure Specification | COMMERCIAL |
ANPZ | Inclosure Feature | DRIPPROOF PROTECTED-45 DEG |
AFYS | Keyway Length | 2.5000 INCHES NOMINAL SINGLE END |
ABRR | Keyway Width | 0.2500 INCHES NOMINAL SINGLE END |
ABRV | Keyway Depth | 0.1200 INCHES NOMINAL SINGLE END |
CWCS | Length Of Shaft From Housing | 2.940 INCHES SINGLE END |
CNXS | Power Rating | 5.0000 HORSEPOWER OUTPUT |
CWFX | Rotor Speed Rating In Rpm | 1745.0 HIGH FULL LOAD |
ABWV | Shaft Diameter | 1.1250 INCHES NOMINAL SINGLE END |
CWHZ | Shaft End Characteristic | A9 SINGLE STYLE SINGLE END |
CWDM | Shaft Center To Mounting Surface Distance | 4.500 INCHES SINGLE END |
AKCT | Shaft Rotation Direction | CLOCKWISE SINGLE END |
AAJT | Overall Height | 9.120 INCHES |
AAJV | Overall Width | 12.570 INCHES |
FAAZ | Phase | THREE INPUT |
BKPH | Torque Rating And Type | 100.0 FOOT-POUNDS RUNNING |
AXCP | Winding Type | INDUCTION-SQUIRREL CAGE |
CWDY | Temp Rating | 80.0 AMBIENT DEG CELSIUS |
TTQY | Terminal Type And Quantity | 3 BINDING POST |