Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
13-0004 | 3 - Design Control Reference | 2 - Production Item | WARD LEONARD ELECTRIC CO INC | 20019 | ![]() |
998431-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | RAYTHEON COMPANY | 49956 | ![]() |
998431-1 | 7 - Vendor Item Drawing Reference | 2 - Production Item | RAYTHEON TECHNICAL SERVICES COMPANY | 3B150 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6105 | 012673513 | A271A0 | 00530 | X | 1 | A | N | A | 10 Nov 1987 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZH01 | 1 Apr 1991 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 2 | 9Z | 13-0004 | 20019 | ![]() | ||||||
5 | 9 | 5 | 9Z | B | 998431-1 | 49956 | ![]() | |||||
7 | 2 | 5 | 9Z | 998431-1 | 3B150 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
DLIS-K, Battle Creek, MI 49037-3084
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 10 Nov 1987 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
9Z |
DLIS-K, Battle Creek, MI 49037-3084
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AKPS | Duty Cycle | CONTINUOUS |
BYDT | Bearing Type | ANNULAR BALL |
CWGQ | Connection Type And Voltage Rating In Volts | 208.0 LINE TO LINE SINGLE INPUT |
BFMF | Cooling Method | FAN COOLED |
CWGL | Current Rating In Amps | 72.000 SINGLE INPUT |
BKPB | Current Rating Method | LOAD |
CBBL | Features Provided | THERMAL PROTECTIVE DEVICE |
FREQ | Frequency In Hertz | 50.0 INPUT |
AXHR | Mounting Facility Type And Quantity | 4 UNTHREADED HOLE |
AXGY | Mounting Method | FIXED BASE |
CWDT | Nominal Center To Center Distance Between Mounting Facilities Parallel To Length | 7.000 INCHES |
CWFY | Nominal Center To Center Distance Between Mounting Facilities Parallel To Width | 8.500 INCHES |
AAJU | Overall Length | 20.500 INCHES |
ANPZ | Inclosure Feature | TOTALLY INCLOSED |
AFYS | Keyway Length | 2.416 INCHES NOMINAL SINGLE END |
ABRR | Keyway Width | 0.312 INCHES NOMINAL SINGLE END |
ABRV | Keyway Depth | 0.156 INCHES NOMINAL SINGLE END |
CWCS | Length Of Shaft From Housing | 2.410 INCHES SINGLE END |
CNXS | Power Rating | 7.500 HORSEPOWER OUTPUT |
CWFX | Rotor Speed Rating In Rpm | 1500.0 SINGLE NO LOAD |
CWDM | Shaft Center To Mounting Surface Distance | 5.250 INCHES SINGLE END |
ABWV | Shaft Diameter | 1.375 INCHES NOMINAL SINGLE END |
CWHZ | Shaft End Characteristic | A9 SINGLE STYLE SINGLE END |
AKCT | Shaft Rotation Direction | CLOCKWISE SINGLE END OR COUNTERCLOCKWISE SINGLE END |
AAJT | Overall Height | 11.400 INCHES |
AAJV | Overall Width | 14.380 INCHES |
FAAZ | Phase | THREE INPUT |
BKPH | Torque Rating And Type | 27.0 FOOT-POUNDS RUNNING |
AXCP | Winding Type | INDUCTION-SQUIRREL CAGE |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CWDY | Temp Rating | -30.0 OPERATING DEG CELSIUS AND 52.0 OPERATING DEG CELSIUS |
TTQY | Terminal Type And Quantity | 5 WIRE LEAD |