Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
100A104-8 | 3 - Design Control Reference | 2 - Production Item | GLOBE MOTORS, INC. | 25140 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6105 | 014819735 | A271A0 | 16350 | X | 4 | 6 | A | N | A | A | 0 | 1 Feb 2001 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZR01 | 1 Feb 2001 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 3 | 2 | 4 | 9Z | D | 100A104-8 | 25140 | ![]() |
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
DLIS-K, Battle Creek, MI 49037-3084
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 1 Feb 2001 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AKPS | Duty Cycle | CONTINUOUS |
CWGL | Current Rating In Amps | 2.500 HIGH INPUT |
BKPB | Current Rating Method | LOAD |
AXHR | Mounting Facility Type And Quantity | 2 THREADED HOLE |
AXGY | Mounting Method | FACE |
CWFY | Nominal Center To Center Distance Between Mounting Facilities Parallel To Width | 0.562 INCHES |
AAJU | Overall Length | 3.138 INCHES |
ANPZ | Inclosure Feature | TOTALLY INCLOSED |
BKPQ | Inclosure Specification | COMMERCIAL |
CWCS | Length Of Shaft From Housing | 0.500 INCHES SINGLE END |
CNXS | Power Rating | 0.022 HORSEPOWER OUTPUT OR 16.4 WATTS OUTPUT |
CWFX | Rotor Speed Rating In Rpm | 6200.0 LOW NO LOAD AND 7300.0 HIGH NO LOAD |
CWHZ | Shaft End Characteristic | A1 SINGLE STYLE SINGLE END |
AAJV | Overall Width | 1.500 INCHES |
CXCY | Part Name Assigned By Controlling Agency | DC PERMANENT MAGNET MOTOR |
FEAT | Special Features | N12 VOLT; SHIELDED CABLE 8.000 IN. NOMINAL; CONDUCTOR DIAMETER 0.025 IN.; COVER ALUMINUM; FRAME DIE-CAST ALUMINUM; SHAFT IS PRECISION GROUND THRU-HARDENED 420 STAINLESS STEEL; WINDING INSULATION RATING 130.0 DEG. C |
BKPH | Torque Rating And Type | 3.5 INCH-OUNCES STARTING OR 11.0 INCH-OUNCES STALLED |
TMDN | Type/Model Designation | A-2400 BD MOTOR |
AXCP | Winding Type | PERMANENT MAGNET |
CWDY | Temp Rating | -55.0 OPERATING DEG CELSIUS AND 85.0 OPERATING DEG CELSIUS |