Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
6002608 | 3 - Design Control Reference | 2 - Production Item | NAVAL FACILITIES ENGINEERING COMMAND | 80091 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6110 | 001862537 | T122-G | 02794 | X | K | B | N | U | 9 Mar 1973 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
N2CM | 3 | H | A | D | JN | 1 Apr 1991 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.
An activitiy within the Army is providing depot maintenance support.
Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.
Naval Facilities Expeditionary Logistics Center, Port Hueneme, CA 93043
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 2 | 1 | JN | D | 6002608 | 80091 |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Naval Facilities Expeditionary Logistics Center, Port Hueneme, CA 93043
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | CX | 0 | 27 Jul 1975 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
JS | P | 658 | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Naval ICP, Mechanicsburg, PA 17055-0788
77.5
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
Naval Facilities Expenditionary Logistics Center, Code N42, Bldg 1000 23rd Ave, Port Hueneme, CA 93043
SERVICE/AGENCY-REGULATED (Service/Agency use only.) Issue, transfer or shipment is controlled by authorities above the ICP level to assure proper and equitable distribution. 1. The use or stockage of the item requires release authority based on prior or concurrent justification. 2. Requisitions will be submitted in accordance with Agency/Service requisitioning procedures.
Unclassified
1
NAVY: 2C COG CEEI Material (Major End Item)
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
APNW | Electrical Input Quantity | 1 |
APNZ | Electrical Output Quantity | 7 |
ADJH | Mounting Method | FLOOR |
ZZZT | Nondefinitive Spec/Std Data | II TYPE AND 2 CLASS |
ANSQ | Output Frequency Rating | 60 HERTZ |
APPA | Output Voltage Rating | 120.0 AC VOLTS MINIMUM AND 208.0 AC VOLTS MAXIMUM |
ANPZ | Inclosure Feature | WATERPROOF |
APPY | Input Frequency In Hertz | 60.0 |
ANPM | Input Phase | THREE |
APNX | Input Voltage Rating | 480.0 AC POUNDS PER HOUR WITH RETAINING CHAIN |
ABKW | Overall Height | 40.000 INCHES MAXIMUM |
ABHP | Overall Length | 72.000 INCHES MAXIMUM |
ABMK | Overall Width | 36.000 INCHES MAXIMUM |
ANJG | Panel Material | ALUMINUM |
APCA | Panel Quantity | 1 |
FAAZ | Phase | THREE |
FEAT | Special Features | PORTABLE ASSEMBLED UNIT ARRANGED SO IT CAN BE LIFTED BY A FORK LIFT,PROVIDED W/TOW BAR AND SLED,CONSISTS OF2 3-POLE CIRCUIT BREAKERS,225 AMP,480V,3 3-POLE CIRCUIT BREAKERS,100 AMP,480V,1 3-POLE CIRCUIT BREAKER,70AMP,480V,4 3-POLE CIRCUIT BREAKERS,30 AMP,208V,2 2-POLE CIRCUIT BREAKERS,50 AMP,208V,1 3-POLE CIRCUIT BREAKER,100 AMP,208V,8 GROUND FAULT CIRCUIT BREAKERS,20 AMP,120V CONNECTED TO NEMA RECEPTACLES,3 10KVA,480-120V 10 TRANSFORMERS CONNECTED 480-208V/120 FOR 30KVA CAPACITY,1 GROUND LUG CONNECTOR |