6110-00-404-5800

REGULATOR,VOLTAGE


6110-00-404-5800 (6110004045800, 004045800)
Part Number (1 listing): RT250W
Summary

FSG 61 / FSC 6110

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 8 Aug 1969

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6110-00-404-5800 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
RT250W3 - Design Control Reference9 - No Longer UsedELECTRONIC RESEARCH ASSOCIATES INC  96762      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6110-00-404-5800 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616110004045800A540Z000176XKANU8 Aug 1969
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6110

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical Control Equipment

004045800

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6110-00-404-5800

A540Z0

Federal Item Identification Guide (FIIG_4065)

00176

Item Naming Code (INC_4080)

8 Aug 1969

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6110-00-404-5800 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZH011 Apr 1991
ZF011 Jul 1995
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6110-00-404-5800 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
339548DRT250W  96762  
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

48

Reference Number Action Activity Code (RNAAC_2900)


Federal Aviation Administration, Oklahoma City, OK 73125

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6110-00-404-5800 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
CCX02 May 1978
Code Definitions

C

Item Standardization Code (ISC_2650)


An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

2 May 1978

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6110-00-404-5800 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
48
Code Definitions

48

Originating Activity Code (ORIG_ACTY_CD_4210)


Federal Aviation Administration, Oklahoma City, OK 73125

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6110-00-404-5800 Submit RFQ
MRCDecoded RequirementClear Text Reply
ANADElectronic Device TypeSOLID STATE
AGAVEnd Item IdentificationMODEL PA-7863
ABTHCenter To Center Distance Between Mounting Holes3.312 INCHES NOMINAL AND 4.250 INCHES NOMINAL
ABTBMounting Hole Diameter0.190 INCHES NOMINAL
ABTJMounting Hole Quantity4
ACUNMounting MethodCHASSIS
AFGAOperating Temp Range-20.0/+71.0 DEG CELSIUS
ANPNOutput Current TypeAC
ANPPOutput Voltage Rating In Volts115.0 NOMINAL
ANPZInclosure FeatureDRIPPROOF
ANPMInput PhaseSINGLE
ANPKInput Voltage Rating In Volts105.0 MINIMUM AND 130.0 MAXIMUM
ANPJInput Current TypeAC
ANPLInput Frequency Rating In Hertz47.0 MINIMUM AND 440.0 MAXIMUM
ANBERecovery Time0.160 SECONDS
AMZDRegulation MethodELECTRONIC OR ELECTROMAGNETIC
ANBDRegulation Percent0.200
ABKWOverall Height4.875 INCHES NOMINAL
ABHPOverall Length7.250 INCHES NOMINAL
ABMKOverall Width6.312 INCHES NOMINAL


Back to Top