| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| LM7905CT/NOPB | 3 - Design Control Reference | 2 - Production Item | TEXAS INSTRUMENTS INC | 33809 | |
| 6014626-001 | 5 - Replaced / Discontinued | 2 - Production Item | BAE SYSTEMS NATIONAL SECURITY | 12436 | |
| LM7905CT | 5 - Replaced / Discontinued | 2 - Production Item | TEXAS INSTRUMENTS INC | 33809 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 61 | 6110 | 016204693 | A540Z0 | 00176 | X | 1 | A | N | A | A | 0 | 25 Jul 2013 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| FUGG | FXGG | 0 | 0 | Z | SU | 1 Dec 2013 | ||||||||||||||||||||||||
Not Established
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Ogden Air Logistics Center, Hill AFB, UT 84056-5609
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 2 | A | ZZ | LM7905CT/NOPB | 33809 | | ||||||
| 5 | 2 | A | ZZ | 6014626-001 | 12436 | | ||||||
| 5 | 2 | A | ZZ | LM7905CT | 33809 | | ||||||
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
USA
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 5 | 97 | 0 | 25 Jul 2013 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SU | 590 | Z | 9 | A | H | Z | W | 062920 | Z | 35120 | REGULATORS-INDUCTION-VOLTAGE |
Ogden Air Logistics Center, Hill AFB, UT 84056-5609
Generators and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
No QUP
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
Defense Logistics Agency
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| ANAD | Electronic Device Type | SOLID STATE |
| AGAV | End Item Identification | LINK 16 ALASK |
| AEZF | Circuit Type | SERIES |
| ANAE | Compensation Provided | DIFFERENTIAL CROSS CURRENT |
| ABTB | Mounting Hole Diameter | 0.149 INCHES MINIMUM AND 0.153 INCHES MAXIMUM |
| ABTJ | Mounting Hole Quantity | 1 |
| ACUN | Mounting Method | UNTHREADED HOLE AND PLUG-IN |
| AFGA | Operating Temp Range | +0.0 TO 125.0 DEG CELSIUS |
| ANPQ | Output Current Rating | 2.2 AMPERES MAXIMUM |
| ANPN | Output Current Type | DC |
| ANPP | Output Voltage Rating In Volts | 5.0 NOMINAL |
| ANPZ | Inclosure Feature | GENERAL PURPOSE |
| ANPJ | Input Current Type | DC |
| ANPK | Input Voltage Rating In Volts | 25.0 NOMINAL |
| ANPT | Power Rating | 3.0 WATTS NOMINAL |
| AMZD | Regulation Method | ELECTRONIC |
| ABKW | Overall Height | 0.175 INCHES MINIMUM AND 0.185 INCHES MAXIMUM |
| ABHP | Overall Length | 1.105 INCHES MINIMUM AND 1.155 INCHES MAXIMUM |
| ABMK | Overall Width | 0.400 INCHES NOMINAL |
| CXCY | Part Name Assigned By Controlling Agency | MICROCIRCUIT,LINEAR |