6110-01-633-4780

CONTACTOR,MAGNETIC


6110-01-633-4780 (6110016334780, 016334780)
Part Number (1 listing): LC1D65A6F7
Summary

FSG 61 / FSC 6110

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 24 Nov 2014

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6110-01-633-4780 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
LC1D65A6F73 - Design Control Reference2 - Production ItemSCHNEIDER ELECTRIC USA, INC.  56365    CAGE 56365  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6110-01-633-4780 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616110016334780A541D031517X43ANAA024 Nov 2014
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6110

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical Control Equipment

016334780

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6110-01-633-4780

A541D0

Federal Item Identification Guide (FIIG_4065)

31517

Item Naming Code (INC_4080)

24 Nov 2014

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6110-01-633-4780 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZK011 Nov 2014
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6110-01-633-4780 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43239ZDLC1D65A6F7  56365   CAGE/56365
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG G - FREIGHT DATA | NSN 6110-01-633-4780 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

X2

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6110-01-633-4780 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKPSDuty CycleVARIABLE
ACYNAc Voltage Rating110.0 VOLTS NOMINAL
AFLWActuation MethodMAGNETIC
ANRHAmp Size Rating65.0
AQZFControl TypeLOCAL OR REMOTE
CBBLFeatures ProvidedROHS DIRECTIVE COMPLIANCE
ABFEHazardous Locations/Environmental ProtectionGENERAL PURPOSE
ANCYHorsepower Rating5.0 AND 50.0
ANQCNational Electrical Manufacturers Association Standards DesignDESIGNED PER NEMA STD
ANCNOperating Voltage CharacteristicFULL
ANPZInclosure FeatureGENERAL PURPOSE
CXCYPart Name Assigned By Controlling AgencyTESYS D IEC CONTACTOR NEW TYPE W/EVERLINK,65A,VAC COIL
AGLDPerformance TypeAUTOMATIC OR MANUAL
FEATSpecial FeaturesCONTROL WIRE SIZE IA NO.12 - NO.18 AWG; CONTROL TERMINAL TORQUE IS 8 IB-IN; MOUNTING HARDWARE IS 35MM DIN RAIL,NO.8 SCREW


Back to Top
Back to Top