6110-01-661-4564

PANEL,POWER DISTRIBUTION


6110-01-661-4564 (6110016614564, 016614564)
Part Number (1 listing): AP8886
Summary

FSG 61 / FSC 6110

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 3 Mar 2017

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6110-01-661-4564 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
AP88863 - Design Control Reference2 - Production ItemSCHNEIDER ELECTRIC IT CORPORATION  0MG77      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6110-01-661-4564 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616110016614564T122-G02794X43ANAA03 Mar 2017
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6110

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical Control Equipment

016614564

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6110-01-661-4564

T122-G

Federal Item Identification Guide (FIIG_4065)

02794

Item Naming Code (INC_4080)

3 Mar 2017

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6110-01-661-4564 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YD011 Mar 2017
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6110-01-661-4564 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43249ZDAP8886  0MG77  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG G - FREIGHT DATA | NSN 6110-01-661-4564 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
YD
Code Definitions

YD

Originating Activity Code (ORIG_ACTY_CD_4210)


Israel

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6110-01-661-4564 Submit RFQ
MRCDecoded RequirementClear Text Reply
APNWElectrical Input Quantity1
APNZElectrical Output Quantity42
AMPSCurrent Rating In Amps32.00
ADJHMounting MethodRACK
CXCYPart Name Assigned By Controlling AgencyRACK PDU 2G, METERED, ZEROU, 22.0KW(32A) 17.3KW(24A), 230
AWJNUnpackaged Unit Weight8.72 KILOGRAMS
ALCDUsage DesignPOWER DISTRIBUTION
APPYInput Frequency In Hertz60.00 2ND VOLTAGE RATING
APPYInput Frequency In Hertz50.00 1ST VOLTAGE RATING
APNYInput NeutralPROVIDED
ANPMInput PhaseTHREE SINGLE VOLTAGE RATING
APNXInput Voltage Rating400.00 AC VOLTS NOMINAL SINGLE VOLTAGE RATING
APPCOutput NeutralPROVIDED
APPAOutput Voltage Rating230.00 AC VOLTS NOMINAL SINGLE VOLTAGE RATING
ABFYOverall Depth51.00 MILLIMETERS MAXIMUM
ABKWOverall Height1829.00 MILLIMETERS MAXIMUM
ABMKOverall Width56.00 MILLIMETERS MAXIMUM
APCAPanel Quantity1
FEATSpecial FeaturesBATTERY BACKUP, 30 C13, 12 C19 OUTPUTS


Back to Top