6115-00-074-8830

GENERATOR SET,GASOLINE ENGINE


6115-00-074-8830 (6115000748830, 000748830)
Part Numbers (6 listings): MEP-017A | MILG52732-9 | 13211E6695 | 5GF8XR3100 | J117 | MILG52279 |
Summary

FSG 61 / FSC 6115

DEMIL:

DEMIL INT:

HMIC:

Date Created:

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6115-00-074-8830 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
MEP-017A3 - Design Control Reference2 - Production ItemDEPARTMENT OF DEFENSE PROJECT  30554    CAGE 30554  
MILG52732-94 - Non-Definitive Specification or Standard Document1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
13211E66955 - Replaced / Discontinued2 - Production ItemCECOM LR CENTER  97403    CAGE 97403  
5GF8XR31005 - Replaced / Discontinued9 - No Longer UsedCUMMINS POWER GENERATION INC.  44940    CAGE 44940  
J1175 - Replaced / Discontinued9 - No Longer UsedENGINEERED ELECTRIC COMPANY  93742    CAGE 93742  
MILG522795 - Replaced / Discontinued9 - No Longer UsedMILITARY SPECIFICATIONS  81349    CAGE 81349  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

4 - Non-Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6115-00-074-8830 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616115000748830
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6115

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Generators and Generator Sets, Electrical

000748830

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6115-00-074-8830

Type of Item Identification (TYP_II_4820)


NSN Center Does Not Have An Explanation




Back to Top