6115-00-081-2033

GENERATOR SET,DIESEL ENGINE


6115-00-081-2033 (6115000812033, 000812033)
Part Numbers (4 listings): 66D44466 | MILG26727 | 55D6246-3 | MB17 |
Summary

FSG 61 / FSC 6115

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1963

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6115-00-081-2033 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
66D444663 - Design Control Reference9 - No Longer UsedSACRAMENTO AIR LOGISTICS CENTER  98749      
MILG267274 - Non-Definitive Specification or Standard Document1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
55D6246-35 - Replaced / Discontinued1 - Incomplete Part NumberAIR FORCE LOGISTICS COMMAND  97151      
MB175 - Replaced / Discontinued1 - Incomplete Part NumberDEPARTMENT OF THE AIR FORCE  80049    CAGE 80049  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

4 - Non-Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 6115-00-081-2033 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616115000812033T322-A00476XM9ANU1 Jan 1963
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6115

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Generators and Generator Sets, Electrical

000812033

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6115-00-081-2033

T322-A

Federal Item Identification Guide (FIIG_4065)

00476

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6115-00-081-2033 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZU011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6115-00-081-2033 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3391TAD66D44466  98749  
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

TA

Reference Number Action Activity Code (RNAAC_2900)


Sacramento Air Logistics Center, McClellan AFB, CA 95652-5609

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6115-00-081-2033 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2D405 Dec 1969
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

D4

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


U.S. Army Belvoir Research, Development and, Engineering Center, Fort Belvoir, VA 22060-5606

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

5 Dec 1969

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6115-00-081-2033 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Q590Z9AHZW062075Z34760GENERATORS-ENGINES-COMBINED
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Q

Less Than Carload (LCL_CD_2760)


70

590

Water Commodity Code (WRT_CMDTY_CD_9275)


Generators and Parts, (machinery and parts), (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

062075

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34760

Uniform Freight Classification (UFC_CD_MODF_3040)

GENERATORS-ENGINES-COMBINED

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6115-00-081-2033 Submit RFQ
MRCDecoded RequirementClear Text Reply
AYGYAc Wattage Rating60.0 KILOWATTS AND 60.0 KILOWATTS AND 60.0 KILOWATTS AND 50.0 KILOWATTS AND 45.0 KILOWATTS AND 45.0 KILOWATTS
AZCLAmbient Temp In Deg Celsius25.0
AZBMAutomatic Starting FeatureNOT PROVIDED
AENKCooling MethodRADIATOR
AYSACranking Voltage In Volts24.0
AYHEExcitor TypeSEPARATELY EXCITED
AYHFExcitorNOT INCLUDED
ACZBFrequency Rating60.0 HERTZ NOMINAL AND 60.0 HERTZ NOMINAL AND 60.0 HERTZ NOMINAL AND 50.0 HERTZ NOMINAL AND 50.0 HERTZ NOMINAL AND 50.0 HERTZ NOMINAL
AZCBHousing TypeINCLOSED
AMSBIdentifying Number5SJ4404+21Y5 PART NO.
ACDCCurrent TypeAC
AAXXMounting TypeWHEEL
AKNAInclosure TypeFULLY INCLOSED
AYHBLine To Line Voltage In Volts416.0 AND 208.0 AND 240.0 AND 220.0 AND 190.0 AND 220.0
AYHCLine To Neutral Voltage In Volts240.0 AND 120.0 AND 220.0 AND 110.0
AQGAManufacturer NameGENERAL ELECTRIC CO.
AYHDPower Factor In Percent80.0 AND 80.0 AND 80.0 AND 80.0 AND 80.0 AND 80.0
AAXSPrime Mover Cooling MediumLIQUID
AZBPPrime Mover Identifying NumberNHC4 MODEL NO.
AZBNPrime Mover Manufacturer NameCUMMINS ENGINE CO.
AYQZPrime Mover Starting MethodELECTRIC MOTOR
AZKTRadio Interference SuppressionINCLUDED
ABKWOverall Height74.000 INCHES NOMINAL
ABHPOverall Length115.000 INCHES NOMINAL
ABMKOverall Width68.000 INCHES NOMINAL
FAAZPhaseTHREE AND THREE AND THREE AND THREE AND THREE AND SINGLE
AMWJWinterization FeatureINCLUDED
AZCMTemp Rise Rating In Deg Celsius For Continuous Operation60.0


Back to Top
Back to Top