6115-00-240-0393

GENERATOR SET,GASOLINE ENGINE


6115-00-240-0393 (6115002400393, 002400393)
Part Number : None
Summary

FSG 61 / FSC 6115

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1963

Replacement NSN:

6115-01-150-0367

Replacement Date: 21 Aug 1986

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6115-00-240-0393 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
Code Definitions

FLIS - SEG A - IDENTIFICATION | NSN 6115-00-240-0393 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616115002400393T322-A00477X1ANU1 Jan 1963
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6115

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Generators and Generator Sets, Electrical

002400393

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6115-00-240-0393

T322-A

Federal Item Identification Guide (FIIG_4065)

00477

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6115-00-240-0393 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZH011 Apr 1991
ZU011 Apr 1991
ZW011 Oct 2009
Code Definitions

FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6115-00-240-0393 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3D411CX621 Aug 1986 6115011500367 5 Dec 1969
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

D4

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


U.S. Army Belvoir Research, Development and, Engineering Center, Fort Belvoir, VA 22060-5606

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

CX

Originator of Replacement Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

6

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.

21 Aug 1986

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

6115-01-150-0367

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

5 Dec 1969

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6115-00-240-0393 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Q590Z9AHZW062075Z34760GENERATORS-ENGINES-COMBINED
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Q

Less Than Carload (LCL_CD_2760)


70

590

Water Commodity Code (WRT_CMDTY_CD_9275)


Generators and Parts, (machinery and parts), (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

062075

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34760

Uniform Freight Classification (UFC_CD_MODF_3040)

GENERATORS-ENGINES-COMBINED

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6115-00-240-0393 Submit RFQ
MRCDecoded RequirementClear Text Reply
AFHSAccessory Component Quantity1
AZCGAccessory Component NameCARRYING CASE
AKVYAccessory Controlling AgencyN/A
AKVZAccessory Identifying NumberN/A
AZCLAmbient Temp In Deg Celsius-54.0 AND 51.7
AZBMAutomatic Starting FeatureNOT PROVIDED
AYSACranking Voltage In Volts12.0
AYHADc Wattage Rating2.0 KILOWATTS
ACYRDc Voltage Rating12.0 VOLTS NOMINAL
AYHEExcitor TypeSELF-EXCITED
AZCBHousing TypeOPEN
ACDCCurrent TypeDC
AAXXMounting TypeSKID
AAXSPrime Mover Cooling MediumAIR
AZBNPrime Mover Manufacturer NameN/A
AYQZPrime Mover Starting MethodBATTERY AND MANUALLY BY CRANK
AZKTRadio Interference SuppressionINCLUDED
ABKWOverall Height30.000 INCHES NOMINAL
ABHPOverall Length32.000 INCHES NOMINAL
ABMKOverall Width24.000 INCHES NOMINAL
AMWJWinterization FeatureNOT INCLUDED
AZCMTemp Rise Rating In Deg Celsius For Continuous Operation50.0


Back to Top
Back to Top