Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE |
---|
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6115 | 002400393 | T322-A | 00477 | X | 1 | A | N | U | 1 Jan 1963 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZU01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Oct 2009 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | D4 | 1 | 1 | CX | 6 | 21 Aug 1986 | 6115011500367 | 5 Dec 1969 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
U.S. Army Belvoir Research, Development and, Engineering Center, Fort Belvoir, VA 22060-5606
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Q | 590 | Z | 9 | A | H | Z | W | 062075 | Z | 34760 | GENERATORS-ENGINES-COMBINED |
70
Generators and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AFHS | Accessory Component Quantity | 1 |
AZCG | Accessory Component Name | CARRYING CASE |
AKVY | Accessory Controlling Agency | N/A |
AKVZ | Accessory Identifying Number | N/A |
AZCL | Ambient Temp In Deg Celsius | -54.0 AND 51.7 |
AZBM | Automatic Starting Feature | NOT PROVIDED |
AYSA | Cranking Voltage In Volts | 12.0 |
AYHA | Dc Wattage Rating | 2.0 KILOWATTS |
ACYR | Dc Voltage Rating | 12.0 VOLTS NOMINAL |
AYHE | Excitor Type | SELF-EXCITED |
AZCB | Housing Type | OPEN |
ACDC | Current Type | DC |
AAXX | Mounting Type | SKID |
AAXS | Prime Mover Cooling Medium | AIR |
AZBN | Prime Mover Manufacturer Name | N/A |
AYQZ | Prime Mover Starting Method | BATTERY AND MANUALLY BY CRANK |
AZKT | Radio Interference Suppression | INCLUDED |
ABKW | Overall Height | 30.000 INCHES NOMINAL |
ABHP | Overall Length | 32.000 INCHES NOMINAL |
ABMK | Overall Width | 24.000 INCHES NOMINAL |
AMWJ | Winterization Feature | NOT INCLUDED |
AZCM | Temp Rise Rating In Deg Celsius For Continuous Operation | 50.0 |