6115-00-329-3583

GENERATOR SET,DIESEL ENGINE


6115-00-329-3583 (6115003293583, 003293583)
Part Number (1 listing): WLW6018A
Summary

FSG 61 / FSC 6115

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1963

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6115-00-329-3583 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
WLW6018A3 - Design Control Reference2 - Production ItemSTEWART & STEVENSON POWER PRODUCTS  81381    CAGE 81381  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6115-00-329-3583 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616115003293583T322-A00476XM4ANU1 Jan 1963
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6115

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Generators and Generator Sets, Electrical

003293583

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6115-00-329-3583

T322-A

Federal Item Identification Guide (FIIG_4065)

00476

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

4

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist but technical data sufficient for preparation of a full descriptive method item identification could not be acquired after several follow-up actions during a 150-day suspense period. Includes such reasons as: Industry refuses to provide the technical data based on policy, restricted or proprietary rights, non-existence of technical data, etc. (This code cannot be used in submittals for National Item Identification Number (NIIN) assignment or reinstatement.)

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6115-00-329-3583 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
ZU011 Apr 1991
ZW011 Nov 2005
Code Definitions

FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6115-00-329-3583 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597023 Dec 1975
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

23 Dec 1975

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6115-00-329-3583 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Q590Z9AHZW062075Z34760GENERATORS-ENGINES-COMBINED
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Q

Less Than Carload (LCL_CD_2760)


70

590

Water Commodity Code (WRT_CMDTY_CD_9275)


Generators and Parts, (machinery and parts), (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

062075

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34760

Uniform Freight Classification (UFC_CD_MODF_3040)

GENERATORS-ENGINES-COMBINED

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6115-00-329-3583 Submit RFQ
MRCDecoded RequirementClear Text Reply
BBJCDocument Controlling AgencyUSAF
AJKADocument IdentificationNO. 35C2-3-198-1
AJJZDocument TypeTECHNICAL MANUAL
AYGYAc Wattage Rating60.0 KILOWATTS AND 50.0 KILOWATTS
AZCLAmbient Temp In Deg Celsius51.000
AZBMAutomatic Starting FeatureNOT PROVIDED
AENKCooling MethodRADIATOR
AYSACranking Voltage In Volts24.000
AYHEExcitor TypeSELF-EXCITED
ACZBFrequency Rating60.0 HERTZ NOMINAL AND 60.0 HERTZ NOMINAL
AZCBHousing TypeINCLOSED
AMSBIdentifying Number14378 MODEL NO.
ACDCCurrent TypeAC AND AC
AAXXMounting TypeSKID
AKNAInclosure TypeFULLY INCLOSED
AYHBLine To Line Voltage In Volts416.0 AND 208.0
AQGAManufacturer NameDELCO
AYHDPower Factor In Percent0.8 AND 0.8
AAXSPrime Mover Cooling MediumLIQUID
AZBPPrime Mover Identifying Number471-RC55 MODEL NO.
AZBNPrime Mover Manufacturer NameGENERAL ELECTRIC CO
AYQZPrime Mover Starting MethodELECTRIC MOTOR
AZKTRadio Interference SuppressionINCLUDED
ABKWOverall Height46.000 INCHES NOMINAL
ABHPOverall Length120.000 INCHES NOMINAL
ABMKOverall Width40.750 INCHES NOMINAL
FAAZPhaseTHREE AND THREE
AMWJWinterization FeatureNOT INCLUDED
AZCMTemp Rise Rating In Deg Celsius For Continuous Operation65.000


Back to Top
Back to Top