6115-00-500-0614

GENERATOR SET,DIESEL ENGINE


6115-00-500-0614 (6115005000614, 005000614)
Part Number (1 listing): 4002
Summary

FSG 61 / FSC 6115

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1963

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6115-00-500-0614 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
40023 - Design Control Reference1 - Incomplete Part NumberHARSCO CORP  93568    CAGE 93568  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 6115-00-500-0614 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616115005000614T322-A00476XLANU1 Jan 1963
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6115

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Generators and Generator Sets, Electrical

005000614

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6115-00-500-0614

T322-A

Federal Item Identification Guide (FIIG_4065)

00476

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

L

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference - Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6115-00-500-0614 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZH011 Apr 1991
ZU011 Apr 1991
ZW011 Nov 2005
Code Definitions

FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6115-00-500-0614 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2CX17 Dec 1994
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

7 Dec 1994

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6115-00-500-0614 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Q590Z9AHZW062075Z34760GENERATORS-ENGINES-COMBINED
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Q

Less Than Carload (LCL_CD_2760)


70

590

Water Commodity Code (WRT_CMDTY_CD_9275)


Generators and Parts, (machinery and parts), (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

062075

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34760

Uniform Freight Classification (UFC_CD_MODF_3040)

GENERATORS-ENGINES-COMBINED

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6115-00-500-0614 Submit RFQ
MRCDecoded RequirementClear Text Reply
AYGYAc Wattage Rating60.0 KILOWATTS AND 60.0 KILOWATTS AND 50.0 KILOWATTS
AZCLAmbient Temp In Deg Celsius25.000
AZBMAutomatic Starting FeatureNOT PROVIDED
AENKCooling MethodRADIATOR
AYSACranking Voltage In Volts24.000
AYHEExcitor TypeSEPARATELY EXCITED
AYHFExcitorINCLUDED
ACZBFrequency Rating50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM
AZCBHousing TypeINCLOSED
ACDCCurrent TypeAC
AAXXMounting TypeSKID
AKNAInclosure TypeFULLY INCLOSED
AYHBLine To Line Voltage In Volts416.0 AND 208.0 AND 50.0
AYHCLine To Neutral Voltage In Volts240.0 AND 120.0 AND 240.0
AYHDPower Factor In Percent0.8 AND 0.8 AND 0.8
AAXSPrime Mover Cooling MediumLIQUID
AYQZPrime Mover Starting MethodELECTRIC MOTOR
AZKTRadio Interference SuppressionINCLUDED
ZZZYReference Number Differentiating CharacteristicsNOT INTERIZED
ABKWOverall Height73.250 INCHES NOMINAL
ABHPOverall Length120.000 INCHES NOMINAL
ABMKOverall Width44.000 INCHES NOMINAL
FAAZPhaseTHREE AND THREE AND THREE
AMWJWinterization FeatureNOT INCLUDED
AZCMTemp Rise Rating In Deg Celsius For Continuous Operation50.000


Back to Top
Back to Top