6115-00-635-9566

GENERATOR,ALTERNATING CURRENT


6115-00-635-9566 (6115006359566, 006359566)
Part Number (1 listing): 101307
Summary

FSG 61 / FSC 6115

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1963

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6115-00-635-9566 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
1013073 - Design Control Reference9 - No Longer UsedARNOLD A. SEMLER, INC.  50870      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6115-00-635-9566 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616115006359566A271A000781XM9ANU1 Jan 1963
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6115

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Generators and Generator Sets, Electrical

006359566

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6115-00-635-9566

A271A0

Federal Item Identification Guide (FIIG_4065)

00781

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6115-00-635-9566 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZP011 Apr 1991
ZU011 Apr 1991
Code Definitions

FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6115-00-635-9566 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2D407 Oct 1972
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

D4

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


U.S. Army Belvoir Research, Development and, Engineering Center, Fort Belvoir, VA 22060-5606

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

7 Oct 1972

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6115-00-635-9566 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Q590Z9AHZW062120Z34760GENERATORS-MOTORS-PARTS-NOI1
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Q

Less Than Carload (LCL_CD_2760)


70

590

Water Commodity Code (WRT_CMDTY_CD_9275)


Generators and Parts, (machinery and parts), (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

062120

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34760

Uniform Freight Classification (UFC_CD_MODF_3040)

GENERATORS-MOTORS-PARTS-NOI

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6115-00-635-9566 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKPSDuty CycleCONTINUOUS
CWGQConnection Type And Voltage Rating In Volts208.0 LINE TO LINE SINGLE OUTPUT OR 120.0 LINE TO NEUTRAL SINGLE OUTPUT
AYHEExcitor TypeSELF-EXCITED
FREQFrequency In Hertz60.0 OUTPUT
CWFQMounting Facility Circle Diameter20.375 INCHES
AXHRMounting Facility Type And Quantity12 UNTHREADED HOLE
AAJUOverall Length26.875 INCHES
ANPZInclosure FeatureDRIPPROOF-15 DEG
BKPQInclosure SpecificationMIL-STD-108
CWCSLength Of Shaft From Housing4.500 INCHES SINGLE END
CNXSPower Rating20.000 KILOWATTS OUTPUT
CWFXRotor Speed Rating In Rpm1800.0 SINGLE FULL LOAD
ABWVShaft Diameter2.0000 INCHES NOMINAL SINGLE END
CWHZShaft End CharacteristicA12 SINGLE STYLE SINGLE END
AKCTShaft Rotation DirectionCOUNTERCLOCKWISE SINGLE END
AAJVOverall Width22.000 INCHES
FAAZPhaseTHREE OUTPUT
AXCPWinding TypeSYNCHRONOUS
ABGHStep Diameter1.219 INCHES NOMINAL SECOND END
ABGHStep Diameter1.750 INCHES NOMINAL FIRST END
CWDYTemp Rating40.0 AMBIENT DEG CELSIUS


Back to Top