Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
73021 | 3 - Design Control Reference | 1 - Incomplete Part Number | NAVAL SHIP SYSTEMS COMMAND | 80064 | ![]() |
73021 | 3 - Design Control Reference | 1 - Incomplete Part Number | NAVAL SHIP SYSTEMS COMMAND | 80064 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6115 | 006433698 | T322-A | 00477 | X | N | 4 | A | N | U | 1 Jan 1961 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference - Descriptive Item Identification (Type 1B Concept)
An approved item name and FIIG may exist but technical data sufficient for preparation of a full descriptive method item identification could not be acquired after several follow-up actions during a 150-day suspense period. Includes such reasons as: Industry refuses to provide the technical data based on policy, restricted or proprietary rights, non-existence of technical data, etc. (This code cannot be used in submittals for National Item Identification Number (NIIN) assignment or reinstatement.)
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 1 | 6 | 9Z | D | 73021 | 80064 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
DLIS-K, Battle Creek, MI 49037-3084
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
1 | D4 | 6 | 3 | D4 | 1 | 21 Oct 1968 | 6115005000287 | 21 Oct 1968 |
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
U.S. Army Belvoir Research, Development and, Engineering Center, Fort Belvoir, VA 22060-5606
Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Q | 590 | Z | 9 | A | H | Z | W | 062075 | Z | 34760 | GENERATORS-ENGINES-COMBINED |
70
Generators and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
BBJC | Document Controlling Agency | BUSHIPS |
AJKA | Document Identification | NAVSHIPS 91086 |
AJJZ | Document Type | SERVICE MANUAL |
AGAV | End Item Identification | MODEL FAH |
AYGY | Ac Wattage Rating | 550.0 KILOWATTS |
AZCL | Ambient Temp In Deg Celsius | 50.0 |
AZBM | Automatic Starting Feature | NOT PROVIDED |
AYHA | Dc Wattage Rating | 500.0 KILOWATTS |
ACYR | Dc Voltage Rating | 28.0 VOLTS NOMINAL |
AYHE | Excitor Type | SEPARATELY EXCITED |
AYHF | Excitor | INCLUDED |
ACZB | Frequency Rating | 800.0 HERTZ NOMINAL |
AZCB | Housing Type | OPEN |
ACDC | Current Type | AC AND DC |
AERL | Maximum Weight Capacity | 200.000 POUNDS |
AAXX | Mounting Type | BASE |
AKSJ | Item Name Assigned By Government Agency | GASOLINE ENGINE GENERATOR SET |
AYHB | Line To Line Voltage In Volts | 115.0 |
FAAZ | Phase | SINGLE |
AYHD | Power Factor In Percent | 1.8 |
AAXS | Prime Mover Cooling Medium | AIR |
AYQZ | Prime Mover Starting Method | MANUALLY BY ROPE |
AZKT | Radio Interference Suppression | INCLUDED |
ZZZY | Reference Number Differentiating Characteristics | W/SPARES |
ABKW | Overall Height | 19.500 INCHES NOMINAL |
ABHP | Overall Length | 29.000 INCHES NOMINAL |
ABMK | Overall Width | 18.500 INCHES NOMINAL |
AMWJ | Winterization Feature | NOT INCLUDED |