Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
4000-144 | 3 - Design Control Reference | 1 - Incomplete Part Number | HARSCO CORP | 93568 | ![]() |
PU361A | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | DEPARTMENT OF THE AIR FORCE | 80049 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6115 | 008105256 | T322-A | 00476 | X | N | 6 | A | N | U | 1 Jan 1962 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference - Descriptive Item Identification (Type 1B Concept)
An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZU01 | 1 Apr 1991 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 23 Dec 1975 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
590 | Z | 9 | A | V | Z | W | 062120 | Z | 34760 | GENERATORS-MOTORS-PARTS-NOI |
Generators and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AYGY | Ac Wattage Rating | 60.0 KILOWATTS |
AZCL | Ambient Temp In Deg Celsius | 54.0 |
AZBM | Automatic Starting Feature | NOT PROVIDED |
AENK | Cooling Method | RADIATOR |
AYSA | Cranking Voltage In Volts | 24.0 |
AGAV | End Item Identification | SM-80 |
AYHE | Excitor Type | SEPARATELY EXCITED |
AYHF | Excitor | INCLUDED |
ACZB | Frequency Rating | 60.0 HERTZ NOMINAL |
AZCB | Housing Type | OPEN |
AMSB | Identifying Number | PART NO. E1330D1329M914 |
ACDC | Current Type | AC |
AAXX | Mounting Type | SKID SHOCK |
AKSJ | Item Name Assigned By Government Agency | GENERATOR SET |
AYHB | Line To Line Voltage In Volts | 208.0 |
AQGA | Manufacturer Name | KURZ AND ROOT |
AYHD | Power Factor In Percent | 0.8 |
AZBP | Prime Mover Identifying Number | PART NO. 6DC-844 |
AZBN | Prime Mover Manufacturer Name | BUDA CO |
AYQZ | Prime Mover Starting Method | ELECTRIC MOTOR |
AAXS | Prime Mover Cooling Medium | LIQUID |
AZKT | Radio Interference Suppression | INCLUDED |
ZZZY | Reference Number Differentiating Characteristics | EXCEPT AS MODIFIED BY AF DWG 61H40463 |
ABKW | Overall Height | 62.500 INCHES NOMINAL |
ABHP | Overall Length | 121.000 INCHES NOMINAL |
ABMK | Overall Width | 37.000 INCHES NOMINAL |
FAAZ | Phase | THREE |
AMWJ | Winterization Feature | NOT INCLUDED |
AZCM | Temp Rise Rating In Deg Celsius For Continuous Operation | 50.0 |