6115-01-251-3697

GENERATOR SET,DIESEL ENGINE


6115-01-251-3697 (6115012513697, 012513697)
Part Numbers (3 listings): AD39651-11 | 12.0DJC-18R/9923AD | AD39651 |
Summary

FSG 61 / FSC 6115

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 18 Mar 1987

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6115-01-251-3697 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
AD39651-111 - Source of Control Reference3 - Reparable ItemHAMILTON SUNDSTRAND CORPORATION  73030      
12.0DJC-18R/9923AD3 - Design Control Reference3 - Reparable ItemCUMMINS POWER GENERATION INC.  44940    CAGE 44940  
AD39651D - Drawing Number Reference9 - No Longer UsedHAMILTON SUNDSTRAND CORPORATION  73030      
Code Definitions

1 - Source of Control Reference

Reference Number Category Code (DRN_2910)


Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

D - Drawing Number Reference

Reference Number Category Code (DRN_2910)


Drawing Number Reference. A number assigned by a design activity to a drawing or other technical documentation which identifies a drawing/document that is related to an item of supply or production but does not qualify for assignment of codes 1,3,5,7, or C. Code D reference numbers will not be used in item-of-supply determinations.

3 - Reparable Item

Reference Number Variation Code (DRN_4780)


A vendor's reference (part) number on a source control item, as defined in MIL-STD-100A, which is reparable through the removal, exchange, and reinstallation of component parts. The related source control document number will also reflect the code 3. This code is limited to a type 1B or 4B item identification.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6115-01-251-3697 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616115012513697T322-A00476XLANA018 Mar 1987
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6115

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Generators and Generator Sets, Electrical

012513697

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6115-01-251-3697

T322-A

Federal Item Identification Guide (FIIG_4065)

00476

Item Naming Code (INC_4080)

18 Mar 1987

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

L

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference - Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6115-01-251-3697 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
FUU400FJFH1 Aug 2011
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

F

Nonconsumable Item Material Support Code (NIMSC_0076)


An activity within the Air Force is providing depot maintenance support.

J

Item Management Code (IMC_2744)


Design Unstable: Items determined by technical decision during the provisioning cycle, during introduction into logistic systems, or at time of item management coding, to be highly subject to either: (A) Design change of the item itself, or (B) Replacement of the item itself through modification of the applicable next-higher assembly. These items will be reviewed for recording when an IM is notified that the item is used by another service/agency, when the design becomes stabilized, or when the item has been in operational use for two years. In all cases these shall be reviewed by IM for IMC change no longer than two years after the IMC J assignment.

FHDSOR

Depot Source of Repair Codes (DSOR_0903)


Ogden Air Logistics Center (OO-ALC), Hill AFB, UT


FLIS - SEG C - REFERENCE NUMBER | NSN 6115-01-251-3697 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
132SBAD39651-11  73030  
332SB12.0DJC-18R/9923AD  44940   CAGE/44940
D92SBAD39651  73030  
Code Definitions

1

Reference Number Category Code (RNCC_2910)


Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)

3

Reference Number Variation Code (RNVC_4780)


A vendor's reference (part) number on a source control item, as defined in MIL-STD-100A, which is reparable through the removal, exchange, and reinstallation of component parts. The related source control document number will also reflect the code 3. This code is limited to a type 1B or 4B item identification.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

SB

Reference Number Action Activity Code (RNAAC_2900)


645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

D

Reference Number Category Code (RNCC_2910)


Drawing Number Reference. A number assigned by a design activity to a drawing or other technical documentation which identifies a drawing/document that is related to an item of supply or production but does not qualify for assignment of codes 1,3,5,7, or C. Code D reference numbers will not be used in item-of-supply determinations.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6115-01-251-3697 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597018 Mar 1987
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

18 Mar 1987

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6115-01-251-3697 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
SU593W9AHDQ062120C34760GENERATORS-MOTORS-PARTS-NOI-SUB3
Code Definitions

SU

Originating Activity Code (ORIG_ACTY_CD_4210)


Ogden Air Logistics Center, Hill AFB, UT 84056-5609

593

Water Commodity Code (WRT_CMDTY_CD_9275)


Motors and Parts, (machinery and parts), (less than 35 feet)

W

Type Cargo Code (TYPE_CGO_CD_9260)


Corrosive materials, UN class 8 (corrosive label)

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

D

Air Special Handling Code (AIR_CMTY_HDLG_9215)


Hazardous material (not required hand to hand receipt) including all regulated items other than special weapons and their components.

Q

Less Than Truckload (CLAS_RTNG_CD_2770)


70

062120

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

C

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34760

Uniform Freight Classification (UFC_CD_MODF_3040)

GENERATORS-MOTORS-PARTS-NOI-SUB3

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6115-01-251-3697 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFFGZVU1TEA0
Code Definitions

FGZ

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Ogden Air Logistics Center, 5851 F Ave, Hill AFB, UT 84056-5713

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

T

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XD2: AF Recoverable Assembly Management System (AFRAMS); NAVY: Terminal Items

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6115-01-251-3697 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGAVEnd Item IdentificationPEACEKEEPER T&H
AYGYAc Wattage Rating12.0 KILOWATTS
AZCLAmbient Temp In Deg Celsius-40.0 AND 55.0
AZBMAutomatic Starting FeatureNOT PROVIDED
AYSACranking Voltage In Volts12.0
AYHEExcitor TypeSELF-EXCITED
ACZBFrequency Rating60.0 HERTZ NOMINAL
AZCBHousing TypeOPEN
ACDCCurrent TypeAC
AAXXMounting TypeBASE SHOCK
AYHBLine To Line Voltage In Volts208.0
AYHCLine To Neutral Voltage In Volts120.0
AYHDPower Factor In Percent80.0
AYQZPrime Mover Starting MethodBATTERY
AAXSPrime Mover Cooling MediumAIR
AZBPPrime Mover Identifying Number12.0DJC-18R/9923AD MODEL NO.
AZBNPrime Mover Manufacturer NameONAN
AZKTRadio Interference SuppressionINCLUDED
ZZZYReference Number Differentiating CharacteristicsAS DIFFERENTIATED BY REPAIR PARTS
ABKWOverall Height27.000 INCHES NOMINAL
ABHPOverall Length48.000 INCHES NOMINAL
ABMKOverall Width24.000 INCHES NOMINAL
FAAZPhaseTHREE
FEATSpecial FeaturesOUTPUT VOLTAGE IS RE-CONNECTABLE TO PROVIDE THE FOLLOWING VOLTAGES:120/208,127/220,139/240,120/240,240/416,254/440,277/480
AWJNUnpackaged Unit Weight710.000 POUNDS
AMWJWinterization FeatureINCLUDED
AZCMTemp Rise Rating In Deg Celsius For Continuous Operation-35.0 AND 40.0


Back to Top
Back to Top