6115-01-284-8572

GENERATOR,ALTERNATING CURRENT


6115-01-284-8572 (6115012848572, 012848572)
Part Number (1 listing): G-81/U
Summary

FSG 61 / FSC 6115

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 2 Sep 1988

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6115-01-284-8572 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
G-81/U3 - Design Control Reference2 - Production ItemJOINT ELECTRONICS TYPE DESIGNATION  80058    CAGE 80058  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6115-01-284-8572 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616115012848572A271A000781NM6ANAA02 Sep 1988
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6115

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Generators and Generator Sets, Electrical

012848572

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6115-01-284-8572

A271A0

Federal Item Identification Guide (FIIG_4065)

00781

Item Naming Code (INC_4080)

2 Sep 1988

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

N

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input).

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

6

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6115-01-284-8572 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
A503A50200V1 Jan 2008
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

V

Item Management Code (IMC_2744)


Non-procured: Stand alone consumable items which are not procured and will not be transferred to DLA for management. (PICA AAC must be V, X, or Y, PICA LOA must be 06 or 23, ISC may not be 1, 3, B, or E, and there must be no I&S phrase codes.)


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6115-01-284-8572 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59702 Sep 1988
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

2 Sep 1988

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6115-01-284-8572 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Q72DZ9AHZP062120A34760GENERATORS-MOTORS-PARTS-NOI-SUB1
Code Definitions

CU

Originating Activity Code (ORIG_ACTY_CD_4210)


Q

Less Than Carload (LCL_CD_2760)


70

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

062120

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

A

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34760

Uniform Freight Classification (UFC_CD_MODF_3040)

GENERATORS-MOTORS-PARTS-NOI-SUB1

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6115-01-284-8572 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DAB16YU1ZEA0
DAB16YU1EA0
Code Definitions

B16

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


US Army Communications-Electronics, Command and Fort Monmout, Fort Monmouth, NJ 07703-5016

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

Z

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6115-01-284-8572 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKPSDuty CycleCONTINUOUS
CWGLCurrent Rating In Amps11.700 HIGH INPUT
CWGLCurrent Rating In Amps4.400 HIGH OUTPUT
FREQFrequency In Hertz400.0 OUTPUT
FREQFrequency In Hertz60.0 INPUT
AXHRMounting Facility Type And Quantity4 UNTHREADED HOLE
AXGYMounting MethodFIXED BASE
AAJUOverall Length11.000 INCHES
ANPZInclosure FeatureINDUSTRIAL
AAJTOverall Height8.000 INCHES
AAJVOverall Width7.700 INCHES
FAAZPhaseSINGLE INPUT
FAAZPhaseSINGLE OUTPUT
FEATSpecial FeaturesCOOL OPERATION; VERY LOW AUDIBLE NOISE; EXTREMELY LOW R.F. NOISE; LIGHTWEIGHT; HIGH OVERLOAD CAPACITY; WITHSTANDS SHORT CIRCUITS; STABLE OUTPUT VOLTAGE; LOW INTERNAL IMPEDANCE; OPERATESIN ADVERSE ENVIRONMENTS


Back to Top
Back to Top