Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
04-1030 | 3 - Design Control Reference | 2 - Production Item | CUMMINS POWER GENERATION INC. | 44940 | ![]() |
MEP-1030 | 3 - Design Control Reference | 2 - Production Item | DEPARTMENT OF DEFENSE PROJECT | 30554 | ![]() |
04-1030 | D - Drawing Number Reference | 9 - No Longer Used | DEPARTMENT OF DEFENSE PROJECT | 30554 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Drawing Number Reference. A number assigned by a design activity to a drawing or other technical documentation which identifies a drawing/document that is related to an item of supply or production but does not qualify for assignment of codes 1,3,5,7, or C. Code D reference numbers will not be used in item-of-supply determinations.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6115 | 015617329 | T322-A | 00476 | X | 1 | A | N | A | A | 0 | 17 Mar 2008 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A502 | 2 | G | A | D | LK | 1 Mar 2008 | ||||||||||||||||||||||||
MA46 | 2 | G | 3 | D | LK | 1 Mar 2008 | ||||||||||||||||||||||||
NSLL | 2 | G | 3 | D | CN | JN | 1 Oct 2011 | |||||||||||||||||||||||
F5CL | 2 | G | 1 | D | FR | 1 May 2013 | ||||||||||||||||||||||||
ZE01 | 1 Nov 2016 |
Suitable for competitive acquisition for the first. time. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.
An activitiy within the Army is providing depot maintenance support.
Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.
End Item Primary Inventory Control Activity. This code identifies SICA managed end items or equipment assigned to another service PICA that is responsible for the wholesale logistics support functions of single submitter of cataloging data, acquisition and disposal authority and depot maintenance, if required, to be provided by DMISA. Supply support requirements will be submitted by the SICA to the PICA on MIPRs unless otherwise directed by the PICA. The SICA is responsible for the wholesale stock, store, and issue functions for SICA activities. The SICA CMD will reflect Source of Supply or SOS Modifiers compatible with the SICA managing activity. The PICA will not be entered in the DAAS IMM field.
Exception Item (End Item of Equipment). This code identifies SICA managed end items of equipment assigned to another service PICA that is responsible for the wholesale logistics support functions of single submitter of cataloging data, acquisition and disposal authority. Supply support requirements will be submitted by the SICA to the PICA on Military Interdepartmental Purchase Requests (MIPRs) unless otherwise directed by the PICA. The SICA is responsible for the wholesale stock, store, and issue functions in support of SICA activities and has retained depot repair capability where applicable. Retention of depot maintenance capability for end items of equipment requires documented justification by the SICA to the PICA via JLC Form 19. If PICA and SICA cannot reach an agreement the documentation will be forwarded to the joint MISMOs for a decision. The SICA Catalog Management Data (CMD) will reflect Source of Supply or SOS Modifiers compatible with the SICA managing activity. The PICA will not be entered in the Defense Automatic Addressing System Integrated Materiel Manager (DAAS IMM) field.
Letterkenny Army Depot (LEAD), Chambersburg, PA
Contract, Contiguous United States (CONUS)
Warner-Robins Air Logistics Center (WR-ALC), Robins AFB, GA
Naval Facilities Expeditionary Logistics Center, Port Hueneme, CA 93043
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 1 | ZZ | MEP-1030 | 30554 | ![]() | ||||||
3 | 2 | 5 | ZZ | 04-1030 | 44940 | ![]() | ||||||
D | 9 | 1 | ZZ | 04-1030 | 30554 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
USA
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Drawing Number Reference. A number assigned by a design activity to a drawing or other technical documentation which identifies a drawing/document that is related to an item of supply or production but does not qualify for assignment of codes 1,3,5,7, or C. Code D reference numbers will not be used in item-of-supply determinations.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 17 Mar 2008 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CL |
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
No Variation. NMFC and UFCC Match.
Commanding General, Marine Corps Logistics Command, 566–2, Bldg. 3700, Albany, GA 31704-5000
SERVICE/AGENCY-REGULATED (Service/Agency use only.) Issue, transfer or shipment is controlled by authorities above the ICP level to assure proper and equitable distribution. 1. The use or stockage of the item requires release authority based on prior or concurrent justification. 2. Requisitions will be submitted in accordance with Agency/Service requisitioning procedures.
Unclassified
No QUP
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
US Army Communications-Electronics, Command and Fort Monmout, Fort Monmouth, NJ 07703-5016
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
ARMY: If condemned or uneconomically repairable, then dispose at intermediate level; COAST GUARD: Reparable item. Repair, condemnation, and disposal not authorized below intermediate (district) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at fourth echelon level; NAVY: Depot Level Reparable
U.S. Marine Corps
Department of the Army
Department of the Navy
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AGAV | End Item Identification | MEP-1030 |
AYGY | Ac Wattage Rating | 5.0 KILOWATTS |
AZCL | Ambient Temp In Deg Celsius | -31.7 |
AZBM | Automatic Starting Feature | NOT PROVIDED |
AENK | Cooling Method | RADIATOR |
AYSA | Cranking Voltage In Volts | 24.0 |
ACZB | Frequency Rating | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
FTLD | Functional Description | TACTICAL SKID MOUNTED POWER SOURCE,CLASS 2B UTILITY,OPERATES ON DIESEL OR JP8 FUELS,USES STANDARD MILITARY OIL AND COOLANTS. |
AZCB | Housing Type | INCLOSED |
ACDC | Current Type | AC |
AAXX | Mounting Type | SKID |
AKNA | Inclosure Type | FULLY INCLOSED |
AYHB | Line To Line Voltage In Volts | 208.0 |
AYHD | Power Factor In Percent | 80.0 |
AAXS | Prime Mover Cooling Medium | LIQUID |
AYQZ | Prime Mover Starting Method | ELECTRIC MOTOR |
AZKT | Radio Interference Suppression | INCLUDED |
RTSE | Relationship To Similar Equipment | THE 5KW AMMPS GENERATOR WILL REPLACE THE 5KW TQGS IN THE FIELD,PRESENTING A LIGHTER,MORE FUEL EFFICIENT SET WITH SMALL LOGISTICS FOOTPRINT. |
ABKW | Overall Height | 35.750 INCHES NOMINAL |
ABHP | Overall Length | 69.750 INCHES NOMINAL |
ABMK | Overall Width | 35.750 INCHES NOMINAL |
FAAZ | Phase | THREE |
FEAT | Special Features | ELECTRICAL OUTPUT RECONNECTABLE FOR 120VOLT,SINGLE PHASE,2WIRE;120/240VOLT,SINGLE PHASE,3WIRE;OR 120/208VOLT,THREE PHASE,4WIRE. |
TMDN | Type/Model Designation | PU-825/G |
AWJN | Unpackaged Unit Weight | 750.000 POUNDS |
AMWJ | Winterization Feature | NOT INCLUDED |
AZCM | Temp Rise Rating In Deg Celsius For Continuous Operation | 90.0 |