6117-01-599-4571

SOLAR CELL PANEL


6117-01-599-4571 (6117015994571, 015994571)
Part Number (1 listing): S20-02130
Summary

FSG 61 / FSC 6117

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 28 Sep 2011

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6117-01-599-4571 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
S20-021303 - Design Control Reference2 - Production ItemCOOPER NOTIFICATION, INC.  1J5K2      
S20-021303 - Design Control Reference2 - Production ItemCOOPER NOTIFICATION, INC.  1J5K2      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6117-01-599-4571 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616117015994571T139-A38183X1ANAA028 Sep 2011
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6117

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Solar Electric Power Systems

015994571

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6117-01-599-4571

T139-A

Federal Item Identification Guide (FIIG_4065)

38183

Item Naming Code (INC_4080)

28 Sep 2011

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG C - REFERENCE NUMBER | NSN 6117-01-599-4571 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43259ZDS20-02130  1J5K2  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6117-01-599-4571 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597628 Sep 2011
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

6

NIIN Status Code (NIIN_STAT_CD_2670)


Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.

28 Sep 2011

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6117-01-599-4571 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
XA
Code Definitions

XA

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Threat Reduction Agency, ATTN: DTRA/NOCO, Kirtland AFB, NM 87117-5669

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6117-01-599-4571 Submit RFQ
MRCDecoded RequirementClear Text Reply
ELECVoltage In Volts17.4
SHPEShapeRECTANGULAR
AARATerminal Quantity1
ABMKOverall Width59.0 INCHES NOMINAL
ABHPOverall Length26.1 INCHES NOMINAL
ABKWOverall Height0.125 INCHES NOMINAL
FEATSpecial FeaturesTHIS IS USED ON THE COOPER NOTIFICATION HPSA (HIGH-POWERED-SPEAKER-ARRAY) AND MSA (MOBILE-SPEAKER-ARRAY) PRODUCTS. MAXIUM POWER IS 130W.


Back to Top
Back to Top