6120-01-600-9116

POWER SUPPLY


6120-01-600-9116 (6120016009116, 016009116)
Part Numbers (2 listings): AFM120PS24 | G27-1510-199 |
Summary

FSG 61 / FSC 6120

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 29 Dec 2011

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6120-01-600-9116 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
AFM120PS243 - Design Control Reference2 - Production ItemXP POWER INC.  1VWD9      
G27-1510-1995 - Replaced / Discontinued2 - Production ItemGRID DEFENCE SYSTEMS LTD  K4F45      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6120-01-600-9116 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616120016009116A3990000740X1ANA829 Dec 2011
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6120

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Transformers: Distribution and Power Station

016009116

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6120-01-600-9116

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

29 Dec 2011

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

8

ADPE Identification Code (ADPEC_0801)


ADP Components. Represents ADP component assemblies that are parts of analog, digital, or hybrid data processing devices.


FLIS - SEG B - MOE RULE DATA | NSN 6120-01-600-9116 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZK011 Dec 2011
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6120-01-600-9116 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43249ZDAFM120PS24  1VWD9  
1524ZKAG27-1510-199  K4F45  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

ZK

Reference Number Action Activity Code (RNAAC_2900)


United Kingdom

A

Reference Number Status Code (RNSC_2923)


Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6120-01-600-9116 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597029 Dec 2011
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

29 Dec 2011

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6120-01-600-9116 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
XA
Code Definitions

XA

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Threat Reduction Agency, ATTN: DTRA/NOCO, Kirtland AFB, NM 87117-5669

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6120-01-600-9116 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKWCElectrical Power Source RelationshipOPERATING
ANRQFrequency Regulation Percent5.0 SINGLE POWER OUTPUT
AKAEMaximum Operating Altitude Rating3000.0 METERS
AYNHOperating Ambient Temp Range+0.0/+70.0 DEG CELSIUS
CWHFOutput Connection Quantity1 SINGLE POWER OUTPUT
CWHJOutput Connection TypeCONNECTOR, PLUG SINGLE POWER OUTPUT
CWHCOutput Control LocationREAR PANEL SINGLE POWER OUTPUT
CWGHOutput Current Rating5.0 DC AMPERES NOMINAL SINGLE POWER OUTPUT
APPAOutput Voltage Rating24.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT
BGQROutput Wattage Rating120.0 WATTS NOMINAL SINGLE POWER OUTPUT
APTQInput Frequency Rating47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT
CWHTInput Connection Quantity1 SINGLE OPERATING POWER RQMT
CWHQInput Connection TypeRECEPTACLE, ELECTRICAL SINGLE OPERATING POWER RQMT
CWHMInput Current Rating1.0 AC AMPERES MINIMUM SINGLE OPERATING POWER RQMT AND 2.0 AC AMPERES MAXIMUM SINGLE OPERATING POWER RQMT
ANPMInput PhaseSINGLE SINGLE OPERATING POWER RQMT
APNXInput Voltage Rating90.0 AC VOLTS MINIMUM SINGLE OPERATING POWER RQMT AND 264.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT
AMQYInstallation DesignFLOOR OR BENCH
BHQNRectification MethodINVERTER AC TO DC
ABKWOverall Height1.400 INCHES NOMINAL
ABHPOverall Length6.790 INCHES NOMINAL
ABMKOverall Width2.790 INCHES NOMINAL
CXCYPart Name Assigned By Controlling AgencyAFM120 AC-DC POWER SUPPLY
FEATSpecial Features47.2-INCH OUTPUT CABLE


Back to Top
Back to Top