Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
7901048-04 | 3 - Design Control Reference | 2 - Production Item | LOCKHEED MARTIN CORPORATION | 90536 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6125 | 003531369 | A271A0 | 00830 | X | M | 6 | A | N | U | 2 Feb 1974 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZF01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZU01 | 1 Aug 2005 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 3 | 2 | 4 | 9Z | D | 7901048-04 | 90536 |
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
DLIS-K, Battle Creek, MI 49037-3084
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 98 | 0 | 1 Feb 1975 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZF | Q | 593 | Z | 9 | A | H | Z | W | 062120 | Z | 34760 | GENERATORS-MOTORS-PARTS-NOI | 1 |
France
70
Motors and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AKPS | Duty Cycle | CONTINUOUS |
CWGQ | Connection Type And Voltage Rating In Volts | 187.2 LINE TO LINE LOW OUTPUT OR 228.8 LINE TO LINE HIGH OUTPUT |
CWGQ | Connection Type And Voltage Rating In Volts | 187.2 LINE TO NEUTRAL FIRST MULTIPLE INPUT OR 228.8 LINE TO NEUTRAL SECOND MULTIPLE INPUT |
BFMF | Cooling Method | AMBIENT AIR |
ACDC | Current Type | AC INPUT |
CBBL | Features Provided | HORIZONTAL MOUNTING POSITION |
FREQ | Frequency In Hertz | 60.0 INPUT |
AXHR | Mounting Facility Type And Quantity | 4 UNTHREADED HOLE |
CWDT | Nominal Center To Center Distance Between Mounting Facilities Parallel To Length | 15.500 INCHES |
CWFY | Nominal Center To Center Distance Between Mounting Facilities Parallel To Width | 12.500 INCHES |
AAJU | Overall Length | 31.310 INCHES |
CNXS | Power Rating | 7.500 KILOWATTS INPUT |
FEAT | Special Features | 115 VAC LINE TO LINE 3 PHASE 4 WIRE OUTPUT,FULL LOAD FREQ 410 HZ PORM 5 PCT,NO LOAD FREQ 420 HZ PORM 5 PCT,INPUT VOLTAGE MAY BE CONVERTED TO 416 V PORM 10 PCT BY CHANGING MOTOR CONNECTIONS |
AAJT | Overall Height | 15.500 INCHES |
AAJV | Overall Width | 15.120 INCHES |
FAAZ | Phase | THREE INPUT |