6125-01-059-5174

MOTOR-GENERATOR


6125-01-059-5174 (6125010595174, 010595174)
Part Number (1 listing): VF021250ADFHKQSVYZ-2-3-4-5
Summary

FSG 61 / FSC 6125

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 12 Apr 1978

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6125-01-059-5174 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
VF021250ADFHKQSVYZ-2-3-4-53 - Design Control Reference2 - Production ItemPOWER PARAGON INC  04801    CAGE 04801  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6125-01-059-5174 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616125010595174A271A000830XM6ANU12 Apr 1978
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6125

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Rotating

010595174

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6125-01-059-5174

A271A0

Federal Item Identification Guide (FIIG_4065)

00830

Item Naming Code (INC_4080)

12 Apr 1978

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

6

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6125-01-059-5174 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
FGG4FAA43HFDFR1 Sep 2000
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

H

Acquisition Method Suffix Code (AMSC_2876)


The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

F

Nonconsumable Item Material Support Code (NIMSC_0076)


An activity within the Air Force is providing depot maintenance support.

D

Item Management Code (IMC_2744)


Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.

FRDSOR

Depot Source of Repair Codes (DSOR_0903)


Warner-Robins Air Logistics Center (WR-ALC), Robins AFB, GA


FLIS - SEG C - REFERENCE NUMBER | NSN 6125-01-059-5174 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
324ZZVF021250ADFHKQSVYZ-2-3-4-5  04801   CAGE/04801
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6125-01-059-5174 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
CCX07 Nov 1981
Code Definitions

C

Item Standardization Code (ISC_2650)


An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

7 Nov 1981

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6125-01-059-5174 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TAW590Z9AHZW062120Z34760GENERATORS-MOTORS-PARTS-NOI
Code Definitions

TA

Originating Activity Code (ORIG_ACTY_CD_4210)


Sacramento Air Logistics Center, McClellan AFB, CA 95652-5609

W

Less Than Carload (LCL_CD_2760)


Rating Variable

590

Water Commodity Code (WRT_CMDTY_CD_9275)


Generators and Parts, (machinery and parts), (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

062120

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34760

Uniform Freight Classification (UFC_CD_MODF_3040)

GENERATORS-MOTORS-PARTS-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6125-01-059-5174 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFFLZXU1SEA0
Code Definitions

FLZ

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Warner Robins Air Logistics Center, 455 Byron St, Robins AFB, GA 31098-1860

X

Acquisition Advice Code (AAC_2507)


SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

S

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC ND2: AF Equipment Management System (AFEMS); NAVY: Slow Demand Velocity Items (Consumables)

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6125-01-059-5174 Submit RFQ
MRCDecoded RequirementClear Text Reply
CWGQConnection Type And Voltage Rating In Volts480.0 LINE TO NEUTRAL SINGLE INPUT
CWGLCurrent Rating In Amps370.000 SINGLE INPUT
ACDCCurrent TypeAC INPUT
FREQFrequency In Hertz60.0 INPUT
CWFXRotor Speed Rating In Rpm1200.0 SINGLE FULL LOAD
FAAZPhaseTHREE INPUT


Back to Top