Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
5C0254G264/5K213MN6768 | 3 - Design Control Reference | 2 - Production Item | GENERAL ELECTRIC CO | 01288 | ![]() |
5C0254G264/5K213MN6768 | 3 - Design Control Reference | 2 - Production Item | GENERAL ELECTRIC CO | 01288 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6125 | 012064718 | A271A0 | 00830 | X | K | A | N | A | 18 Apr 1985 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 6 | 18 Apr 1985 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AKPS | Duty Cycle | CONTINUOUS |
CWGQ | Connection Type And Voltage Rating In Volts | 440.0 KONICA, C TORQUE SET INPUT |
BFMF | Cooling Method | AMBIENT AIR |
CWGL | Current Rating In Amps | 11.000 SINGLE INPUT |
CWGL | Current Rating In Amps | 36.000 SINGLE OUTPUT |
ACDC | Current Type | DC OUTPUT |
ACDC | Current Type | AC INPUT |
CBBL | Features Provided | HORIZONTAL MOUNTING POSITION |
CBME | Cubic Measure | 16.000 CUBIC FEET |
CWFQ | Mounting Facility Circle Diameter | 0.812 INCHES |
AXHR | Mounting Facility Type And Quantity | 4 UNTHREADED HOLE |
AXGY | Mounting Method | BED PLATE |
CWDT | Nominal Center To Center Distance Between Mounting Facilities Parallel To Length | 38.000 INCHES |
CWFY | Nominal Center To Center Distance Between Mounting Facilities Parallel To Width | 11.374 INCHES |
AAJU | Overall Length | 39.500 INCHES |
ANPZ | Inclosure Feature | DRIPPROOF-15 DEG |
BKPQ | Inclosure Specification | NEMA |
CNXS | Power Rating | 4.500 KILOWATTS OUTPUT |
CNXS | Power Rating | 7.500 HORSEPOWER INPUT |
AAJT | Overall Height | 16.281 INCHES |
AAJV | Overall Width | 18.062 INCHES |
FEAT | Special Features | DESIGN CONTROL REFERENCE SPEC 180-CGY-S61-16 |
CWDY | Temp Rating | 50.0 AMBIENT DEG CELSIUS |
TTQY | Terminal Type And Quantity | 3 WIRE LEAD |