6130-00-090-8930

POWER SUPPLY


6130-00-090-8930 (6130000908930, 000908930)
Part Number (1 listing): 0EM20N3.8-1
Summary

FSG 61 / FSC 6130

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 29 Nov 1972

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-00-090-8930 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
0EM20N3.8-13 - Design Control Reference2 - Production ItemASTEC AMERICA INC.  08742    CAGE 08742  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6130-00-090-8930 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130000908930A3990000740XKANU29 Nov 1972
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

000908930

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-00-090-8930

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

29 Nov 1972

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6130-00-090-8930 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Sep 2003
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6130-00-090-8930 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
4323CXD0EM20N3.8-1  08742   CAGE/08742
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

CX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Richmond, Richmond, VA 23297-5000

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6130-00-090-8930 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2CX08 Feb 1976
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

8 Feb 1976

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6130-00-090-8930 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
CX
Code Definitions

CX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Richmond, Richmond, VA 23297-5000

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-00-090-8930 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKWCElectrical Power Source RelationshipOPERATING
CBBLFeatures ProvidedFILTER
AYNHOperating Ambient Temp Range+0.1 TO 71.0 DEG CELSIUS
CWHFOutput Connection Quantity2 SINGLE POWER OUTPUT
CWGHOutput Current Rating2.5 DC AMPERES MINIMUM SINGLE POWER OUTPUT AND 3.8 DC AMPERES MAXIMUM SINGLE POWER OUTPUT
CWHJOutput Connection TypeTERMINAL STRIP SINGLE POWER OUTPUT
BGHXOutput Control Quantity1 SINGLE POWER OUTPUT
BGHYOutput Control TypeVOLTAGE ADJUSTMENT SINGLE POWER OUTPUT
APPAOutput Voltage Rating20.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT
APTQInput Frequency Rating47.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT
APTQInput Frequency Rating47.0 HERTZ MINIMUM 2ND OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT
APNXInput Voltage Rating210.0 AC VOLTS MINIMUM AND 250.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 2ND OPERATING POWER RQMT
ANPMInput PhaseSINGLE 2ND OPERATING POWER RQMT
ANPMInput PhaseSINGLE 1ST OPERATING POWER RQMT
APNXInput Voltage Rating105.0 AC POUNDS PER HOUR DRY AND 125.0 AC VOLTS MAXIMUM 1ST OPERATING POWER RQMT
BHQNRectification MethodSINGLE PHASE FULL WAVE BRIDGE
ABKWOverall Height4.940 INCHES NOMINAL
ABHPOverall Length10.000 INCHES NOMINAL
ABMKOverall Width3.190 INCHES NOMINAL