6130-00-295-5806

POWER SUPPLY


6130-00-295-5806 (6130002955806, 002955806)
Part Number (1 listing): 343D826G01
Summary

FSG 61 / FSC 6130

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 22 Sep 1973

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-00-295-5806 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
343D826G013 - Design Control Reference2 - Production ItemNORTHROP GRUMMAN SYSTEMS CORPORATION  97942    CAGE 97942  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6130-00-295-5806 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130002955806A3990000740XKANU22 Sep 1973
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

002955806

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-00-295-5806

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

22 Sep 1973

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6130-00-295-5806 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZH011 Aug 1995
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6130-00-295-5806 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
332548D343D826G01  97942   CAGE/97942
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

48

Reference Number Action Activity Code (RNAAC_2900)


Federal Aviation Administration, Oklahoma City, OK 73125

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6130-00-295-5806 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2CX06 Feb 1982
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

6 Feb 1982

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6130-00-295-5806 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
48
Code Definitions

48

Originating Activity Code (ORIG_ACTY_CD_4210)


Federal Aviation Administration, Oklahoma City, OK 73125

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-00-295-5806 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKWCElectrical Power Source RelationshipOPERATING
CWHJOutput Connection TypeCONNECTOR, RECEPTACLE SINGLE POWER OUTPUT
BGHXOutput Control Quantity1 SINGLE POWER OUTPUT
BGHYOutput Control TypeVOLTAGE ADJUSTMENT SINGLE POWER OUTPUT
CWHFOutput Connection Quantity1 SINGLE POWER OUTPUT
CWGHOutput Current Rating300.0 DC MICROAMPERES NOMINAL SINGLE POWER OUTPUT
APPAOutput Voltage Rating17.0 DC KILOVOLTS NOMINAL SINGLE POWER OUTPUT
CWHTInput Connection Quantity1 SINGLE OPERATING POWER RQMT
CWHQInput Connection TypeCONNECTOR, PLUG SINGLE OPERATING POWER RQMT
CWHMInput Current Rating1.0 DC AMPERES NOMINAL SINGLE OPERATING POWER RQMT
APNXInput Voltage Rating50.0 DC VOLTS NOMINAL SINGLE OPERATING POWER RQMT
BHQNRectification MethodSINGLE PHASE FULL WAVE BRIDGE
ABKWOverall Height4.490 INCHES NOMINAL
ABHPOverall Length4.940 INCHES NOMINAL
ABMKOverall Width4.328 INCHES NOMINAL


Back to Top