6130-00-444-4825

POWER SUPPLY


6130-00-444-4825 (6130004444825, 004444825)
Part Number (1 listing): 410B
Summary

FSG 61 / FSC 6130

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 23 Dec 1970

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-00-444-4825 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
410B3 - Design Control Reference2 - Production ItemFLUKE CORPORATION  89536    CAGE 89536  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6130-00-444-4825 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130004444825A3990000740XKANU23 Dec 1970
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

004444825

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-00-444-4825

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

23 Dec 1970

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6130-00-444-4825 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC011 Apr 1991
ZG011 Apr 1991
ZK011 Apr 1991
ZS011 Apr 1991
YB011 Oct 2004
ZW011 Nov 2005
YK011 Jan 2015
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6130-00-444-4825 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
4322SED410B  89536   CAGE/89536
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

SE

Reference Number Action Activity Code (RNAAC_2900)


San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6130-00-444-4825 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2CX08 Feb 1976
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

8 Feb 1976

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6130-00-444-4825 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
SE
Code Definitions

SE

Originating Activity Code (ORIG_ACTY_CD_4210)


San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-00-444-4825 Submit RFQ
MRCDecoded RequirementClear Text Reply
CBBLFeatures ProvidedFILTER
AKAEMaximum Operating Altitude Rating10000.0 FEET
AYNHOperating Ambient Temp Range+0.1/+50.0 DEG CELSIUS
CWGHOutput Current Rating0.0 DC AMPERES MINIMUM SINGLE POWER OUTPUT AND 10.0 DC AMPERES MAXIMUM SINGLE POWER OUTPUT
APPAOutput Voltage Rating0.0 DC VOLTS MINIMUM SINGLE POWER OUTPUT AND 1.0 DC VOLTS MAXIMUM SINGLE POWER OUTPUT
ANPMInput PhaseSINGLE 1ST OPERATING POWER RQMT
ANPMInput PhaseSINGLE 2ND OPERATING POWER RQMT
APTQInput Frequency Rating50.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 60.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT
APTQInput Frequency Rating50.0 HERTZ MINIMUM 2ND OPERATING POWER RQMT AND 60.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT
APNXInput Voltage Rating115.0 AC VOLTS NOMINAL 2ND OPERATING POWER RQMT
APNXInput Voltage Rating230.0 AC VOLTS NOMINAL 1ST OPERATING POWER RQMT
BHQNRectification MethodSINGLE PHASE FULL WAVE CENTER TAP
ABKWOverall Height8.750 INCHES NOMINAL
ABHPOverall Length19.000 INCHES NOMINAL
ABMKOverall Width15.000 INCHES NOMINAL


Back to Top