6130-00-504-1912

POWER SUPPLY


6130-00-504-1912 (6130005041912, 005041912)
Part Numbers (2 listings): R650471-1 | PP-1461/GPS |
Summary

FSG 61 / FSC 6130

DEMIL: B

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1963

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-00-504-1912 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
R650471-13 - Design Control Reference2 - Production ItemRAYTHEON COMPANY  06845    CAGE 06845  
PP-1461/GPS5 - Replaced / Discontinued2 - Production ItemJOINT ELECTRONICS TYPE DESIGNATION  80058    CAGE 80058  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6130-00-504-1912 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130005041912A3990000740NKBNU1 Jan 1963
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

005041912

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-00-504-1912

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

N

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input).

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

B

Demilitarization Code (DEMIL_CD_0167)


MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6130-00-504-1912 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZH011 Apr 1991
B482B4803CT881 Aug 1999
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

C

Acquisition Method Suffix Code (AMSC_2876)


This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.

T

Nonconsumable Item Material Support Code (NIMSC_0076)


A Federal Aviation Administration activity is providing depot maintenance support.

88DSOR

Depot Source of Repair Codes (DSOR_0903)


For agencies excluded from the DSOR program. Not for DoD Service's use.


FLIS - SEG C - REFERENCE NUMBER | NSN 6130-00-504-1912 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3325SBDR650471-1  06845   CAGE/06845
524SBPP-1461/GPS  80058   CAGE/80058
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

SB

Reference Number Action Activity Code (RNAAC_2900)


645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6130-00-504-1912 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TU017 Oct 1973
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TU

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

17 Oct 1973

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6130-00-504-1912 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6130-00-504-1912 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
GEG69CU1EA0
Code Definitions

G69

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Department of Transportation, Federal Aviation Administration, ATTN: COE AML-030 TSF BLDG 215 PO BOX 25082, Oklahoma City, OK 73125-0082

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

GE

Service / Agency Code (MOE_CD_2833)


Federal Aviation Administration


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-00-504-1912 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKWCElectrical Power Source RelationshipOPERATING
AGAVEnd Item IdentificationAN/FPS-20, RECEIVER GROUP OA-1077/FPS-20
CWGHOutput Current Rating190.0 DC MILLIAMPERES NOMINAL 3RD POWER OUTPUT
CWGHOutput Current Rating280.0 DC MILLIAMPERES NOMINAL 2ND POWER OUTPUT
CWGHOutput Current Rating80.0 DC MILLIAMPERES NOMINAL 1ST POWER OUTPUT
APPAOutput Voltage Rating250.0 DC VOLTS NOMINAL 1ST POWER OUTPUT
APPAOutput Voltage Rating120.0 DC VOLTS NOMINAL 2ND POWER OUTPUT
APPAOutput Voltage Rating150.0 DC VOLTS NOMINAL 3RD POWER OUTPUT
ANPMInput PhaseSINGLE SINGLE OPERATING POWER RQMT
APTQInput Frequency Rating60.0 HERTZ NOMINAL SINGLE OPERATING POWER RQMT
APNXInput Voltage Rating120.0 AC POUNDS PER HOUR WET SINGLE OPERATING POWER RQMT
BHQNRectification MethodFULL WAVE VOLTAGE DOUBLER
ABKWOverall Height9.600 INCHES NOMINAL
ABHPOverall Length24.380 INCHES NOMINAL
ABMKOverall Width23.500 INCHES NOMINAL
FEATSpecial FeaturesREFERENCE DATA, FIG 220-5, T.O. 31P6-2FPS20-4, TECHNICAL MANUAL, ILLUSTRATED PARTS BREAKDOWN, RADAR SETS AN/FPS-20, PG 576


Back to Top
Back to Top