6130-00-504-2730

POWER SUPPLY


6130-00-504-2730 (6130005042730, 005042730)
Part Numbers (2 listings): R650270-1 | PP-1301/GPS |
Summary

FSG 61 / FSC 6130

DEMIL: B

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1963

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-00-504-2730 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
R650270-13 - Design Control Reference2 - Production ItemRAYTHEON COMPANY  06845    CAGE 06845  
PP-1301/GPS5 - Replaced / Discontinued2 - Production ItemJOINT ELECTRONICS TYPE DESIGNATION  80058    CAGE 80058  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6130-00-504-2730 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130005042730A3990000740XM3BNU1 Jan 1963
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

005042730

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-00-504-2730

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

B

Demilitarization Code (DEMIL_CD_0167)


MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6130-00-504-2730 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZH011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6130-00-504-2730 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3325TADR650270-1  06845   CAGE/06845
524SBPP-1301/GPS  80058   CAGE/80058
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

TA

Reference Number Action Activity Code (RNAAC_2900)


Sacramento Air Logistics Center, McClellan AFB, CA 95652-5609

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

SB

Reference Number Action Activity Code (RNAAC_2900)


645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6130-00-504-2730 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TU017 Oct 1973
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TU

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

17 Oct 1973

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6130-00-504-2730 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-00-504-2730 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKWCElectrical Power Source RelationshipOPERATING
AGAVEnd Item IdentificationAN/GPS-4 AND AN/FPS-20
ZZZVFsc Application DataRADAR SET,NONAIRBORNE,EXCEPT FIRE CONTROL AND GUIDED MISSILE
CWGHOutput Current Rating5.0 DC MILLIAMPERES NOMINAL 3RD POWER OUTPUT
CWGHOutput Current Rating10.0 DC MILLIAMPERES NOMINAL 2ND POWER OUTPUT
CWGHOutput Current Rating50.0 DC MILLIAMPERES NOMINAL 1ST POWER OUTPUT
CWGHOutput Current Rating500.0 AC MILLIAMPERES NOMINAL 4TH POWER OUTPUT
APPAOutput Voltage Rating20.0 DC VOLTS NOMINAL 3RD POWER OUTPUT
APPAOutput Voltage Rating250.0 DC VOLTS NOMINAL 2ND POWER OUTPUT
APPAOutput Voltage Rating1100.0 DC VOLTS NOMINAL 1ST POWER OUTPUT
APPAOutput Voltage Rating120.0 AC VOLTS NOMINAL 4TH POWER OUTPUT
ANPMInput PhaseSINGLE SINGLE OPERATING POWER RQMT
APTQInput Frequency Rating60.0 HERTZ NOMINAL SINGLE OPERATING POWER RQMT
APNXInput Voltage Rating120.0 AC POUNDS PER HOUR WET SINGLE OPERATING POWER RQMT
AMQYInstallation DesignCABINET WITH COMPLETE HARDWARE
BHQNRectification MethodFULL WAVE VOLTAGE DOUBLER
ABKWOverall Height20.060 INCHES NOMINAL
ABHPOverall Length19.000 INCHES NOMINAL
ABMKOverall Width8.720 INCHES NOMINAL
FEATSpecial FeaturesFILTER INCLUDED


Back to Top
Back to Top