6130-00-778-9487

POWER SUPPLY


6130-00-778-9487 (6130007789487, 007789487)
Part Numbers (2 listings): 9190842 | 851244 |
Summary

FSG 61 / FSC 6130

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1962

Unit Weight: 0.3 lbs

Unit Size:

Unit Pack Cube: 0.011 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-00-778-9487 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
91908423 - Design Control Reference2 - Production ItemU S ARMY AVIATION AND MISSILE  18876    CAGE 18876  
8512445 - Replaced / Discontinued2 - Production ItemADVANCED CONVERSION TECHNOLOGY, INC.  60642      
8512445 - Replaced / Discontinued9 - No Longer UsedTYCO ELECTRONICS CORPORATION  00779    CAGE 00779  
8512445 - Replaced / Discontinued9 - No Longer UsedTYCO ELECTRONICS CORPORATION  2H631      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6130-00-778-9487 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130007789487A3990000740X1ANA01 Jan 1962
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

007789487

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-00-778-9487

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

1 Jan 1962

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6130-00-778-9487 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZF011 Apr 1991
ZH011 Apr 1991
ZS011 Apr 1991
ZU011 Aug 1995
YB011 Sep 2008
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6130-00-778-9487 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
525ZZ851244  60642  
4591CXB851244  00779   CAGE/00779
595CLB851244  2H631  
Code Definitions

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

CX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Richmond, Richmond, VA 23297-5000

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

CL

Reference Number Action Activity Code (RNAAC_2900)


U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6130-00-778-9487 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2CX18 Feb 1976
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

8 Feb 1976

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6130-00-778-9487 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
658Z9AHZM062900X35110RECTIFIERS-NOI-BATTERY-ELIMINATORS
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

M

Less Than Truckload (CLAS_RTNG_CD_2770)


85

062900

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35110

Uniform Freight Classification (UFC_CD_MODF_3040)

RECTIFIERS-NOI-BATTERY-ELIMINATORS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG W - PACKAGING DATA | NSN 6130-00-778-9487 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PA11000.3 lbs0.011 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00XED
Code Definitions

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

A

Item Type Storage Code (ITM_TYP_STOR_5156)


Heated General Purpose – Heated 40 F and above

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

100

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

0.3 lbs

Unit Pack Weight (UP_WT_5153)

0.011 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

ED

Intermediate Container Code (INTMD_CTNR_CD_5167)


ASTM-D5118, Type CF, Class weather resistant, corrugated fiberboard box.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-00-778-9487 Submit RFQ
MRCDecoded RequirementClear Text Reply
BHQNRectification MethodSINGLE PHASE FULL WAVE CENTER TAP
APPAOutput Voltage Rating1.4 DC VOLTS NOMINAL SINGLE POWER OUTPUT
CWGHOutput Current Rating2.5 DC AMPERES NOMINAL SINGLE POWER OUTPUT
BGHYOutput Control TypeFIXED VOLTAGE SINGLE POWER OUTPUT
BGHXOutput Control Quantity1 SINGLE POWER OUTPUT
CWHFOutput Connection Quantity2 SINGLE POWER OUTPUT
CWHJOutput Connection TypeSOLDER LUG SINGLE POWER OUTPUT
AKWCElectrical Power Source RelationshipOPERATING
APNXInput Voltage Rating200.0 AC VOLTS NOMINAL SINGLE OPERATING POWER RQMT
APTQInput Frequency Rating400.0 HERTZ NOMINAL SINGLE OPERATING POWER RQMT
ANPMInput PhaseTHREE SINGLE OPERATING POWER RQMT
AKAEMaximum Operating Altitude Rating10000.0 FEET
ABHPOverall Length4.500 INCHES NOMINAL
ABMKOverall Width2.000 INCHES NOMINAL
ABKWOverall Height4.188 INCHES NOMINAL


Back to Top