Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
711A | 3 - Design Control Reference | 2 - Production Item | HEWLETT PACKARD CO | 28480 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6130 | 008121886 | A39900 | 00740 | X | M | 9 | A | N | U | 1 Jan 1962 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZC01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZS01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
FGG4 | FAA4 | 0 | 0 | X | F | 99 | 1 Sep 2000 | |||||||||||||||||||||||
YA01 | 1 Oct 2000 | |||||||||||||||||||||||||||||
ZR01 | 1 Dec 2007 | |||||||||||||||||||||||||||||
ZM01 | 1 Feb 2015 |
Not Established
All other conditions.
Single Agency: Items assigned to a single agency other than the commodity oriented integrated manager for integrated management or control. (These include items controlled by the Energy Research and Development Administration or National Security Agency, or items assigned to the Army Tank-Automotive Command (TACOM) for integrated management.)
Depot source of repair has not been assigned. This is a temporary code that will be used only until a DSOR is assigned as specified in joint Service regulation AMC-R 750û10, OPNAVINST 4790.14A AFI 21û133(I), MCO P4790.10B, DLAD 4151.16, Joint Depot Maintenance Program, 31 March 1999.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | CX | 0 | 8 Feb 1976 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M | 738 | 3 | 9 | A | H | Z | M | 062900 | X | 35110 | RECTIFIERS-NOI-BATTERY-ELIMINATORS |
85
Computing Equipment, Computer Components, and Circuit Cards
Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
Warner Robins Air Logistics Center, 455 Byron St, Robins AFB, GA 31098-1860
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Unclassified
1
AIR FORCE ERRC NF2: AF Equipment Management System (AFEMS); NAVY: Fast moving centrally managed 1I COG forms (locally procured at selected designated overseas activities)
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 53 | 1 | 000 | 26.5 lbs | 19in x 12in x 18in | 2.375 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | EA | FA | X | ED | 00 | B | 03 | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Floating watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
MIL-DTL-17667, neutral wrapping paper
PPP-C-1120, Class A, water resistant bound fiber
As required to protect the item or elements of the package
ASTM-D5118, Type CF, Class weather resistant, corrugated fiberboard box.
No requirement.
Unit container provides level B packing protection.
Mehod 50
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AKWC | Electrical Power Source Relationship | OPERATING |
ZZZV | Fsc Application Data | 1. POWER SUPPLY,MULTIAPPLICATION |
CWGH | Output Current Rating | 100.0 DC MILLIAMPERES NOMINAL 1ST POWER OUTPUT |
CWGH | Output Current Rating | 3.0 AC AMPERES NOMINAL 2ND POWER OUTPUT |
CWGH | Output Current Rating | 6.0 AC AMPERES NOMINAL 3RD POWER OUTPUT |
APPA | Output Voltage Rating | 0.0 DC VOLTS MINIMUM 1ST POWER OUTPUT AND 500.0 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
APPA | Output Voltage Rating | 12.6 AC VOLTS NOMINAL 2ND POWER OUTPUT |
APPA | Output Voltage Rating | 6.3 AC VOLTS NOMINAL 3RD POWER OUTPUT |
APTQ | Input Frequency Rating | 0.05 KILOHERTZ MINIMUM 1ST OPERATING POWER RQMT AND 1.00 KILOHERTZ MAXIMUM 1ST OPERATING POWER RQMT |
APTQ | Input Frequency Rating | 0.05 KILOHERTZ MINIMUM 2ND OPERATING POWER RQMT AND 1.0 KILOHERTZ MAXIMUM 2ND OPERATING POWER RQMT |
APNX | Input Voltage Rating | 115.0 DC POUNDS PER HOUR WET 1ST OPERATING POWER RQMT |
ANPM | Input Phase | SINGLE 2ND OPERATING POWER RQMT |
ANPM | Input Phase | SINGLE 1ST OPERATING POWER RQMT |
APNX | Input Voltage Rating | 230.0 DC POUNDS PER HOUR WET 2ND OPERATING POWER RQMT |
ABKW | Overall Height | 7.375 INCHES NOMINAL |
ABHP | Overall Length | 14.250 INCHES NOMINAL |
ABMK | Overall Width | 11.500 INCHES NOMINAL |
FEAT | Special Features | HALF WAVE RECTIFICATION |