6130-01-006-2876

POWER SUPPLY


6130-01-006-2876 (6130010062876, 010062876)
Part Numbers (3 listings): 227-7078 | 200P100-1T-52 | G300279S1 |
Summary

FSG 61 / FSC 6130

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 15 Jul 1975

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-01-006-2876 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
227-70783 - Design Control Reference2 - Production ItemTECHNIPOWER LLC  13850    CAGE 13850  
200P100-1T-523 - Design Control Reference2 - Production ItemCANBERRA INDUSTRIES, INC.  06442    CAGE 06442  
G300279S17 - Vendor Item Drawing Reference2 - Production ItemEXELIS INC.  24930    CAGE 24930  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

7 - Vendor Item Drawing Reference

Reference Number Category Code (DRN_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6130-01-006-2876 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130010062876A3990000740X1ANU15 Jul 1975
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

010062876

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-01-006-2876

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

15 Jul 1975

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6130-01-006-2876 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZB011 Apr 1991
ZC011 Apr 1991
ZG011 Apr 1991
ZH011 Dec 1997
ZT011 Sep 1998
YK011 Jan 2015
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6130-01-006-2876 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
13249ZD200P100-1T-52  06442   CAGE/06442
13249ZD227-7078  13850   CAGE/13850
17229ZDG300279S1  24930   CAGE/24930
Code Definitions

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

7

Reference Number Category Code (RNCC_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6130-01-006-2876 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597016 Jul 1975
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

16 Jul 1975

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6130-01-006-2876 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
M658Z9AHZM062900X35110RECTIFIERS-NOI-BATTERY-ELIMINATORS
Code Definitions

DL

Originating Activity Code (ORIG_ACTY_CD_4210)


M

Less Than Carload (LCL_CD_2760)


85

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

062900

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35110

Uniform Freight Classification (UFC_CD_MODF_3040)

RECTIFIERS-NOI-BATTERY-ELIMINATORS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-01-006-2876 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKWCElectrical Power Source RelationshipOPERATING
ADZCEnvironmental ProtectionHERMETICALLY SEALED
CBBLFeatures ProvidedFILTER
AYNHOperating Ambient Temp Range-62.0/+115.0 DEG CELSIUS
CWGHOutput Current Rating100.0 DC MILLIAMPERES NOMINAL SINGLE POWER OUTPUT
APPAOutput Voltage Rating192.0 DC VOLTS MINIMUM SINGLE POWER OUTPUT AND 210.0 DC VOLTS MAXIMUM SINGLE POWER OUTPUT
APTQInput Frequency Rating48.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 400.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT
ANPMInput PhaseSINGLE SINGLE OPERATING POWER RQMT
APNXInput Voltage Rating105.0 AC VOLTS MINIMUM SINGLE OPERATING POWER RQMT AND 129.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT
ABKWOverall Height4.312 INCHES NOMINAL
ABHPOverall Length5.562 INCHES NOMINAL
ABMKOverall Width5.062 INCHES NOMINAL
FEATSpecial FeaturesFULL RECTIFICATION


Back to Top
Back to Top