6130-01-073-5427

POWER SUPPLY


6130-01-073-5427 (6130010735427, 010735427)
Part Numbers (2 listings): U5B5-5A | 743454-02 |
Summary

FSG 61 / FSC 6130

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 16 Mar 1979

Unit Weight: None

Unit Size: None

Unit Pack Cube: None

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-01-073-5427 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
U5B5-5A3 - Design Control Reference9 - No Longer UsedMARTEK POWER INCORPORATED  15755      
743454-027 - Vendor Item Drawing Reference2 - Production ItemGE AVIATION SYSTEMS LLC  35351    CAGE 35351  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

7 - Vendor Item Drawing Reference

Reference Number Category Code (DRN_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6130-01-073-5427 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130010735427A3990000740XKANU16 Mar 1979
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

010735427

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-01-073-5427

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

16 Mar 1979

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6130-01-073-5427 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZH011 Nov 1994
YA011 Dec 2001
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6130-01-073-5427 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
4393CXDU5B5-5A  15755  
4721CXD743454-02  35351   CAGE/35351
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

CX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Richmond, Richmond, VA 23297-5000

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

7

Reference Number Category Code (RNCC_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6130-01-073-5427 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2CX06 Feb 1982
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

6 Feb 1982

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6130-01-073-5427 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
CX658Z9ZHJM062900X35110RECTIFIERS-NOI-BATTERY-ELIMINATORS
Code Definitions

CX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Richmond, Richmond, VA 23297-5000

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

Z

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation, but does exceed 72 inches in one or more dimensions.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

J

Air Special Handling Code (AIR_CMTY_HDLG_9215)


Materiel normally hazardous, rendered non-hazardous for shipment processing. (DD Form 1387-2 must certify to that effect.)

M

Less Than Truckload (CLAS_RTNG_CD_2770)


85

062900

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35110

Uniform Freight Classification (UFC_CD_MODF_3040)

RECTIFIERS-NOI-BATTERY-ELIMINATORS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG W - PACKAGING DATA | NSN 6130-01-073-5427 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP101AAA
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00XE500EQO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

10

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Physical protection

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

E5

Unit Container Code (UNIT_CTNR_CD_5166)


ASTM-D5118, fiberboard box.

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

E

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-01-073-5427 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKWCElectrical Power Source RelationshipOPERATING
ADZCEnvironmental ProtectionHERMETICALLY SEALED
CBBLFeatures ProvidedFILTER
CWGHOutput Current Rating10.0 DC AMPERES NOMINAL SINGLE POWER OUTPUT
CWHFOutput Connection Quantity2 SINGLE POWER OUTPUT
CWHJOutput Connection TypeFERRULE SINGLE POWER OUTPUT
BGHXOutput Control Quantity1 SINGLE POWER OUTPUT
CWHCOutput Control LocationTOP PANEL SINGLE POWER OUTPUT
BGHYOutput Control TypeVOLTAGE ADJUSTMENT SINGLE POWER OUTPUT
APPAOutput Voltage Rating4.7 DC VOLTS MINIMUM SINGLE POWER OUTPUT AND 5.3 DC VOLTS MAXIMUM SINGLE POWER OUTPUT
ANPMInput PhaseSINGLE SINGLE OPERATING POWER RQMT
CWHTInput Connection Quantity2 SINGLE OPERATING POWER RQMT
CWHQInput Connection TypeFERRULE SINGLE OPERATING POWER RQMT
APTQInput Frequency Rating380.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 420.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT
APNXInput Voltage Rating105.0 AC VOLTS MINIMUM SINGLE OPERATING POWER RQMT AND 125.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT
ASCXLoad TypeRESISTIVE SINGLE POWER OUTPUT
BHQNRectification MethodSINGLE PHASE FULL WAVE CENTER TAP
ABKWOverall Height1.110 INCHES MINIMUM AND 1.140 INCHES MAXIMUM
ABHPOverall Length5.469 INCHES MINIMUM AND 5.531 INCHES MAXIMUM
ABMKOverall Width3.930 INCHES MINIMUM AND 4.050 INCHES MAXIMUM
FEATSpecial FeaturesBASE TEMPERATURE RATING MINUS 54 DEG C TO 100 DEG C; ALTITUDE RATING SEA LEVEL TO INFINITY