6130-01-085-2927

POWER SUPPLY


6130-01-085-2927 (6130010852927, 010852927)
Part Number (1 listing): EAK-1
Summary

FSG 61 / FSC 6130

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 5 Nov 1979

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-01-085-2927 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
EAK-13 - Design Control Reference9 - No Longer UsedBASIC INC  18794      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6130-01-085-2927 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130010852927A3990000740X1ANA5 Nov 1979
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

010852927

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-01-085-2927

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

5 Nov 1979

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 6130-01-085-2927 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G90000L1 Apr 1991
A918A1783HZCDCL1 Feb 2005
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

L

Acquisition Advice Code (AAC_2507)


LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

H

Acquisition Method Suffix Code (AMSC_2876)


The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

CD

Item Management Coding Activity (IMC_ACTY_2748)


U.S. Army War Reserve Command, New Cumberland, PA 17070-5008

CL

Supplementary Receivers (SUPPLM_RCVR_2534)


U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006


FLIS - SEG C - REFERENCE NUMBER | NSN 6130-01-085-2927 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
4395CXDEAK-1  18794  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

CX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Richmond, Richmond, VA 23297-5000

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6130-01-085-2927 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59705 Nov 1979
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

5 Nov 1979

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6130-01-085-2927 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
CX595Z9AHZM062900X35110RECTIFIERS-NOI-BATTERY-ELIMINATORS
Code Definitions

CX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Richmond, Richmond, VA 23297-5000

595

Water Commodity Code (WRT_CMDTY_CD_9275)


Transformer, (machinery and parts), (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

M

Less Than Truckload (CLAS_RTNG_CD_2770)


85

062900

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35110

Uniform Freight Classification (UFC_CD_MODF_3040)

RECTIFIERS-NOI-BATTERY-ELIMINATORS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6130-01-085-2927 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DASMSJU1ZEA0
DSSMSJU1NEA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

Z

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-01-085-2927 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKWCElectrical Power Source RelationshipOPERATING
CBBLFeatures ProvidedFILTER
AYNHOperating Ambient Temp Range+0.1/+50.0 DEG CELSIUS
CWGHOutput Current Rating600.0 DC MILLIAMPERES NOMINAL 1ST POWER OUTPUT
CWGHOutput Current Rating900.0 DC MILLIAMPERES NOMINAL 2ND POWER OUTPUT
APPAOutput Voltage Rating18.0 DC POUNDS PER HOUR DRY 2ND POWER OUTPUT AND 28.0 DC POUNDS PER HOUR WITH RETAINING CHAIN 2ND POWER OUTPUT
APPAOutput Voltage Rating20.0 DC POUNDS PER HOUR DRY 1ST POWER OUTPUT AND 28.0 DC POUNDS PER HOUR WITH RETAINING CHAIN 1ST POWER OUTPUT
APNXInput Voltage Rating110.0 AC VOLTS NOMINAL SINGLE OPERATING POWER RQMT
APTQInput Frequency Rating60.0 HERTZ NOMINAL SINGLE OPERATING POWER RQMT
ANPMInput PhaseSINGLE SINGLE OPERATING POWER RQMT
BHQNRectification MethodSINGLE PHASE FULL WAVE CENTER TAP
ABKWOverall Height7.000 INCHES NOMINAL
ABHPOverall Length4.875 INCHES NOMINAL
ABMKOverall Width9.500 INCHES NOMINAL


Back to Top
Back to Top