Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
LOT-V-5152-A | 3 - Design Control Reference | 9 - No Longer Used | VEECO INSTRUMENTS INC | 80103 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6130 | 011263249 | A39900 | 00740 | X | 1 | B | N | A | 9 Feb 1982 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZG | ||||||||||||||||||||||||||||||
ZK | ||||||||||||||||||||||||||||||
ZR | ||||||||||||||||||||||||||||||
ZZ | ||||||||||||||||||||||||||||||
ZR01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZG01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZK01 | 1 Jan 1996 | |||||||||||||||||||||||||||||
DGX1 | 3 | H | CX | 1 Feb 2005 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.
Defense Supply Center Richmond, Richmond, VA 23297-5000
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 9 | 3 | CX | LOT-V-5152-A | 80103 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CX | 72D | Z | 9 | A | V | Z | M | 062900 | X | 35110 | RECTIFIERS-NOI-BATTERY-ELIMINATORS |
Defense Supply Center Richmond, Richmond, VA 23297-5000
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above.
No special handling required.
85
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AKWC | Electrical Power Source Relationship | OPERATING |
CBBL | Features Provided | FILTER |
AYNH | Operating Ambient Temp Range | +0.1/+60.0 DEG CELSIUS |
CWHF | Output Connection Quantity | 2 2ND POWER OUTPUT |
CWHF | Output Connection Quantity | 2 3RD POWER OUTPUT |
CWHF | Output Connection Quantity | 2 4TH POWER OUTPUT |
CWHF | Output Connection Quantity | 2 5TH POWER OUTPUT |
CWHF | Output Connection Quantity | 2 1ST POWER OUTPUT |
CWHJ | Output Connection Type | TERMINAL STRIP 1ST POWER OUTPUT |
CWHJ | Output Connection Type | TERMINAL STRIP 3RD POWER OUTPUT |
CWHJ | Output Connection Type | TERMINAL STRIP 4TH POWER OUTPUT |
CWHJ | Output Connection Type | TERMINAL STRIP 5TH POWER OUTPUT |
CWHJ | Output Connection Type | TERMINAL STRIP 2ND POWER OUTPUT |
CWHC | Output Control Location | FRONT PANEL 2ND POWER OUTPUT |
CWHC | Output Control Location | FRONT PANEL 3RD POWER OUTPUT |
CWHC | Output Control Location | FRONT PANEL 4TH POWER OUTPUT |
CWHC | Output Control Location | FRONT PANEL 5TH POWER OUTPUT |
CWHC | Output Control Location | FRONT PANEL 1ST POWER OUTPUT |
BGHX | Output Control Quantity | 1 1ST POWER OUTPUT |
BGHX | Output Control Quantity | 1 2ND POWER OUTPUT |
BGHX | Output Control Quantity | 1 3RD POWER OUTPUT |
BGHX | Output Control Quantity | 1 4TH POWER OUTPUT |
BGHX | Output Control Quantity | 1 5TH POWER OUTPUT |
BGHY | Output Control Type | VOLTAGE ADJUSTMENT 1ST POWER OUTPUT |
BGHY | Output Control Type | VOLTAGE ADJUSTMENT 4TH POWER OUTPUT |
BGHY | Output Control Type | VOLTAGE ADJUSTMENT 5TH POWER OUTPUT |
BGHY | Output Control Type | VOLTAGE ADJUSTMENT 2ND POWER OUTPUT |
BGHY | Output Control Type | VOLTAGE ADJUSTMENT 3RD POWER OUTPUT |
CWGH | Output Current Rating | 5.2 DC AMPERES MINIMUM 2ND POWER OUTPUT AND 9.0 DC AMPERES MAXIMUM 2ND POWER OUTPUT |
CWGH | Output Current Rating | 5.2 DC AMPERES MINIMUM 3RD POWER OUTPUT AND 9.0 DC AMPERES MAXIMUM 3RD POWER OUTPUT |
CWGH | Output Current Rating | 5.2 DC AMPERES MINIMUM 4TH POWER OUTPUT AND 9.0 DC AMPERES MAXIMUM 4TH POWER OUTPUT |
CWGH | Output Current Rating | 5.2 DC AMPERES MINIMUM 5TH POWER OUTPUT AND 9.0 DC AMPERES MAXIMUM 5TH POWER OUTPUT |
CWGH | Output Current Rating | 5.2 DC AMPERES MINIMUM 1ST POWER OUTPUT AND 9.0 DC AMPERES MAXIMUM 1ST POWER OUTPUT |
APPA | Output Voltage Rating | 12.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
APPA | Output Voltage Rating | 15.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
APPA | Output Voltage Rating | -12.0 DC VOLTS NOMINAL 4TH POWER OUTPUT |
APPA | Output Voltage Rating | -15.0 DC VOLTS NOMINAL 5TH POWER OUTPUT |
APPA | Output Voltage Rating | 5.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
CWHQ | Input Connection Type | TERMINAL STRIP 1ST OPERATING POWER RQMT |
CWHQ | Input Connection Type | TERMINAL STRIP 2ND OPERATING POWER RQMT |
APNX | Input Voltage Rating | 105.0 AC VOLTS MINIMUM 2ND OPERATING POWER RQMT AND 125.0 AC VOLTS MAXIMUM 2ND OPERATING POWER RQMT |
APTQ | Input Frequency Rating | 47.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT |
APTQ | Input Frequency Rating | 47.0 HERTZ MINIMUM 2ND OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT |
ANPM | Input Phase | SINGLE 1ST OPERATING POWER RQMT |
ANPM | Input Phase | SINGLE 2ND OPERATING POWER RQMT |
APNX | Input Voltage Rating | 210.0 AC VOLTS MINIMUM 1ST OPERATING POWER RQMT AND 250.0 AC VOLTS MAXIMUM 1ST OPERATING POWER RQMT |
BHQN | Rectification Method | SINGLE PHASE FULL WAVE CENTER TAP |
ABKW | Overall Height | 4.875 INCHES NOMINAL |
ABHP | Overall Length | 4.875 INCHES NOMINAL |
ABMK | Overall Width | 13.750 INCHES NOMINAL |