6130-01-126-3249

POWER SUPPLY


6130-01-126-3249 (6130011263249, 011263249)
Part Number (1 listing): LOT-V-5152-A
Summary

FSG 61 / FSC 6130

DEMIL: B

DEMIL INT: 3

HMIC: N

Date Created: 9 Feb 1982

MSDS: None

Hazmat: None

Export License Required:
Critical Munitions List Item or Sensitive Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-01-126-3249 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
LOT-V-5152-A3 - Design Control Reference9 - No Longer UsedVEECO INSTRUMENTS INC  80103    CAGE 80103  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6130-01-126-3249 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130011263249A3990000740X1BNA9 Feb 1982
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

011263249

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-01-126-3249

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

9 Feb 1982

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

B

Demilitarization Code (DEMIL_CD_0167)


MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 6130-01-126-3249 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZG
ZK
ZR
ZZ
ZR011 Apr 1991
ZG011 Apr 1991
ZK011 Jan 1996
DGX13HCX1 Feb 2005
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

H

Acquisition Method Suffix Code (AMSC_2876)


The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

CX

Supplementary Receivers (SUPPLM_RCVR_2534)


Defense Supply Center Richmond, Richmond, VA 23297-5000


FLIS - SEG C - REFERENCE NUMBER | NSN 6130-01-126-3249 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
393CXLOT-V-5152-A  80103   CAGE/80103
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

CX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Richmond, Richmond, VA 23297-5000


FLIS - SEG G - FREIGHT DATA | NSN 6130-01-126-3249 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
CX72DZ9AVZM062900X35110RECTIFIERS-NOI-BATTERY-ELIMINATORS
Code Definitions

CX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Richmond, Richmond, VA 23297-5000

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

V

Air Commodity Code (AIR_CMTY_HDLG_9215)


Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

M

Less Than Truckload (CLAS_RTNG_CD_2770)


85

062900

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35110

Uniform Freight Classification (UFC_CD_MODF_3040)

RECTIFIERS-NOI-BATTERY-ELIMINATORS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6130-01-126-3249 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DSSMSYU1NEA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-01-126-3249 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKWCElectrical Power Source RelationshipOPERATING
CBBLFeatures ProvidedFILTER
AYNHOperating Ambient Temp Range+0.1/+60.0 DEG CELSIUS
CWHFOutput Connection Quantity2 2ND POWER OUTPUT
CWHFOutput Connection Quantity2 3RD POWER OUTPUT
CWHFOutput Connection Quantity2 4TH POWER OUTPUT
CWHFOutput Connection Quantity2 5TH POWER OUTPUT
CWHFOutput Connection Quantity2 1ST POWER OUTPUT
CWHJOutput Connection TypeTERMINAL STRIP 1ST POWER OUTPUT
CWHJOutput Connection TypeTERMINAL STRIP 3RD POWER OUTPUT
CWHJOutput Connection TypeTERMINAL STRIP 4TH POWER OUTPUT
CWHJOutput Connection TypeTERMINAL STRIP 5TH POWER OUTPUT
CWHJOutput Connection TypeTERMINAL STRIP 2ND POWER OUTPUT
CWHCOutput Control LocationFRONT PANEL 2ND POWER OUTPUT
CWHCOutput Control LocationFRONT PANEL 3RD POWER OUTPUT
CWHCOutput Control LocationFRONT PANEL 4TH POWER OUTPUT
CWHCOutput Control LocationFRONT PANEL 5TH POWER OUTPUT
CWHCOutput Control LocationFRONT PANEL 1ST POWER OUTPUT
BGHXOutput Control Quantity1 1ST POWER OUTPUT
BGHXOutput Control Quantity1 2ND POWER OUTPUT
BGHXOutput Control Quantity1 3RD POWER OUTPUT
BGHXOutput Control Quantity1 4TH POWER OUTPUT
BGHXOutput Control Quantity1 5TH POWER OUTPUT
BGHYOutput Control TypeVOLTAGE ADJUSTMENT 1ST POWER OUTPUT
BGHYOutput Control TypeVOLTAGE ADJUSTMENT 4TH POWER OUTPUT
BGHYOutput Control TypeVOLTAGE ADJUSTMENT 5TH POWER OUTPUT
BGHYOutput Control TypeVOLTAGE ADJUSTMENT 2ND POWER OUTPUT
BGHYOutput Control TypeVOLTAGE ADJUSTMENT 3RD POWER OUTPUT
CWGHOutput Current Rating5.2 DC AMPERES MINIMUM 2ND POWER OUTPUT AND 9.0 DC AMPERES MAXIMUM 2ND POWER OUTPUT
CWGHOutput Current Rating5.2 DC AMPERES MINIMUM 3RD POWER OUTPUT AND 9.0 DC AMPERES MAXIMUM 3RD POWER OUTPUT
CWGHOutput Current Rating5.2 DC AMPERES MINIMUM 4TH POWER OUTPUT AND 9.0 DC AMPERES MAXIMUM 4TH POWER OUTPUT
CWGHOutput Current Rating5.2 DC AMPERES MINIMUM 5TH POWER OUTPUT AND 9.0 DC AMPERES MAXIMUM 5TH POWER OUTPUT
CWGHOutput Current Rating5.2 DC AMPERES MINIMUM 1ST POWER OUTPUT AND 9.0 DC AMPERES MAXIMUM 1ST POWER OUTPUT
APPAOutput Voltage Rating12.0 DC VOLTS NOMINAL 2ND POWER OUTPUT
APPAOutput Voltage Rating15.0 DC VOLTS NOMINAL 1ST POWER OUTPUT
APPAOutput Voltage Rating-12.0 DC VOLTS NOMINAL 4TH POWER OUTPUT
APPAOutput Voltage Rating-15.0 DC VOLTS NOMINAL 5TH POWER OUTPUT
APPAOutput Voltage Rating5.0 DC VOLTS NOMINAL 3RD POWER OUTPUT
CWHQInput Connection TypeTERMINAL STRIP 1ST OPERATING POWER RQMT
CWHQInput Connection TypeTERMINAL STRIP 2ND OPERATING POWER RQMT
APNXInput Voltage Rating105.0 AC VOLTS MINIMUM 2ND OPERATING POWER RQMT AND 125.0 AC VOLTS MAXIMUM 2ND OPERATING POWER RQMT
APTQInput Frequency Rating47.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT
APTQInput Frequency Rating47.0 HERTZ MINIMUM 2ND OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT
ANPMInput PhaseSINGLE 1ST OPERATING POWER RQMT
ANPMInput PhaseSINGLE 2ND OPERATING POWER RQMT
APNXInput Voltage Rating210.0 AC VOLTS MINIMUM 1ST OPERATING POWER RQMT AND 250.0 AC VOLTS MAXIMUM 1ST OPERATING POWER RQMT
BHQNRectification MethodSINGLE PHASE FULL WAVE CENTER TAP
ABKWOverall Height4.875 INCHES NOMINAL
ABHPOverall Length4.875 INCHES NOMINAL
ABMKOverall Width13.750 INCHES NOMINAL


Back to Top
Back to Top