6130-01-141-9260

POWER SUPPLY


6130-01-141-9260 (6130011419260, 011419260)
Part Number (1 listing): OEM28N1.6-1-2-C
Summary

FSG 61 / FSC 6130

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 7 Nov 1982

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-01-141-9260 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
OEM28N1.6-1-2-C3 - Design Control Reference2 - Production ItemASTEC AMERICA INC.  08742    CAGE 08742  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6130-01-141-9260 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130011419260A3990000740X1ANA7 Nov 1982
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

011419260

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-01-141-9260

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

7 Nov 1982

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 6130-01-141-9260 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZH011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6130-01-141-9260 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
32ECXOEM28N1.6-1-2-C  08742   CAGE/08742
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

CX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Richmond, Richmond, VA 23297-5000


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6130-01-141-9260 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59707 Nov 1982
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

7 Nov 1982

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6130-01-141-9260 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
CX
Code Definitions

CX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Richmond, Richmond, VA 23297-5000

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-01-141-9260 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKWCElectrical Power Source RelationshipOPERATING
CBBLFeatures ProvidedFILTER
AYNHOperating Ambient Temp Range+0.1/+71.0 DEG CELSIUS
CWGHOutput Current Rating1.6 DC AMPERES NOMINAL SINGLE POWER OUTPUT
CWHFOutput Connection Quantity2 SINGLE POWER OUTPUT
CWHJOutput Connection TypeTERMINAL STRIP SINGLE POWER OUTPUT
CWHCOutput Control LocationFRONT PANEL SINGLE POWER OUTPUT
BGHXOutput Control Quantity1 SINGLE POWER OUTPUT
BGHYOutput Control TypeVOLTAGE ADJUSTMENT SINGLE POWER OUTPUT
APPAOutput Voltage Rating28.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT
CWHTInput Connection Quantity2 SINGLE OPERATING POWER RQMT
CWHQInput Connection TypeTERMINAL STRIP SINGLE OPERATING POWER RQMT
APNXInput Voltage Rating105.0 AC VOLTS MINIMUM SINGLE OPERATING POWER RQMT AND 125.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT
APTQInput Frequency Rating47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT
ANPMInput PhaseSINGLE SINGLE OPERATING POWER RQMT
BHQNRectification MethodSINGLE PHASE FULL WAVE CENTER TAP
ABKWOverall Height4.940 INCHES NOMINAL
ABHPOverall Length6.250 INCHES NOMINAL
ABMKOverall Width3.190 INCHES NOMINAL