Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
RAX 15-6.6K | 3 - Design Control Reference | 2 - Production Item | KEPCO, INC. | 85604 | ![]() |
RMX15A | 3 - Design Control Reference | 9 - No Longer Used | KEPCO, INC. | 85604 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6130 | 011430750 | A39900 | 00740 | X | 1 | B | N | A | 25 Nov 1982 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YJ01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
FXGG | FXCX | 1 | R | Z | SX | 1 Feb 2005 | ||||||||||||||||||||||||
N9BG | N9GD | 1 | R | Z | HD | HD | 1 Feb 2005 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The data or the rights to use the data needed to purchase this part from additional sources are not owned by the Government and it has been determined that it is uneconomical to purchase them. Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
USA
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
Defense Supply Center Richmond, Richmond, VA 23297-5000
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 25 Nov 1982 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CX | 658 | Z | 9 | A | H | Z | M | 062900 | X | 35110 | RECTIFIERS-NOI-BATTERY-ELIMINATORS |
Defense Supply Center Richmond, Richmond, VA 23297-5000
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
85
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Unclassified
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AKWC | Electrical Power Source Relationship | OPERATING |
AYNH | Operating Ambient Temp Range | +0.1/+71.0 DEG CELSIUS |
CWHF | Output Connection Quantity | 2 SINGLE POWER OUTPUT |
CWHJ | Output Connection Type | TERMINAL STRIP SINGLE POWER OUTPUT |
CWHC | Output Control Location | FRONT PANEL SINGLE POWER OUTPUT |
BGHX | Output Control Quantity | 1 SINGLE POWER OUTPUT |
BGHY | Output Control Type | VOLTAGE ADJUSTMENT SINGLE POWER OUTPUT |
CWGH | Output Current Rating | 4.5 DC AMPERES MINIMUM SINGLE POWER OUTPUT AND 5.0 DC AMPERES MAXIMUM SINGLE POWER OUTPUT |
APPA | Output Voltage Rating | 10.5 DC VOLTS MINIMUM SINGLE POWER OUTPUT AND 16.5 DC VOLTS MAXIMUM SINGLE POWER OUTPUT |
CWHT | Input Connection Quantity | 4 1ST OPERATING POWER RQMT |
CWHT | Input Connection Quantity | 4 2ND OPERATING POWER RQMT |
CWHQ | Input Connection Type | TERMINAL STRIP 1ST OPERATING POWER RQMT |
CWHQ | Input Connection Type | TERMINAL STRIP 2ND OPERATING POWER RQMT |
APNX | Input Voltage Rating | 100.0 AC VOLTS MINIMUM 2ND OPERATING POWER RQMT AND 130.0 AC VOLTS MAXIMUM 2ND OPERATING POWER RQMT |
APTQ | Input Frequency Rating | 47.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT |
APTQ | Input Frequency Rating | 47.0 HERTZ MINIMUM 2ND OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT |
ANPM | Input Phase | SINGLE 1ST OPERATING POWER RQMT |
ANPM | Input Phase | SINGLE 2ND OPERATING POWER RQMT |
APNX | Input Voltage Rating | 200.0 AC VOLTS MINIMUM 1ST OPERATING POWER RQMT AND 260.0 AC VOLTS MAXIMUM 1ST OPERATING POWER RQMT |
BHQN | Rectification Method | SINGLE PHASE FULL WAVE CENTER TAP |
ABKW | Overall Height | 5.120 INCHES NOMINAL |
ABHP | Overall Length | 2.170 INCHES NOMINAL |
ABMK | Overall Width | 8.310 INCHES NOMINAL |