6130-01-164-0547

POWER SUPPLY


6130-01-164-0547 (6130011640547, 011640547)
Part Numbers (2 listings): 30396770-1 | PP-7922/GSQ-215 |
Summary

FSG 61 / FSC 6130

DEMIL: B

DEMIL INT: 3

HMIC: N

Date Created: 12 Oct 1983

MSDS: None

Hazmat: None

Export License Required:
Critical Munitions List Item or Sensitive Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6130-01-164-0547 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
30396770-13 - Design Control Reference9 - No Longer UsedADATUM INC  24672      
PP-7922/GSQ-2155 - Replaced / Discontinued2 - Production ItemJOINT ELECTRONICS TYPE DESIGNATION  80058    CAGE 80058  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6130-01-164-0547 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616130011640547A3990000740NM3BNAA012 Oct 1983
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6130

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Nonrotating

011640547

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6130-01-164-0547

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

12 Oct 1983

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

N

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input).

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

B

Demilitarization Code (DEMIL_CD_0167)


MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6130-01-164-0547 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZZ
A5023HAECLTB1 Apr 1991
NSLL3H4E99GG1 Mar 1994
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

H

Acquisition Method Suffix Code (AMSC_2876)


The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

A

Nonconsumable Item Material Support Code (NIMSC_0076)


An activitiy within the Army is providing depot maintenance support.

E

Item Management Code (IMC_2744)


Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.

CL

Item Management Coding Activity (IMC_ACTY_2748)


U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006

4

Nonconsumable Item Material Support Code (NIMSC_0076)


Depot Reparable Component. (Type I Temporary). This code identifies SICA managed depot reparable components assigned to another service PICA that is responsible for the logistics functions of single submitter of cataloging data, acquisition and disposal authority and depot maintenance to be provided by DMISA. Supply support requirements will be submitted by the SICA to the PICA on MIPRs unless otherwise directed by the PICA. The SICA is responsible for the wholesale stock, store and issue functions for SICA activities. This code is temporarily assigned to items which have not completed Phase II item review processing. The SICA CMD will reflect Source of Supply or SOS Modifiers compatible with the SICA managing activity. The PICA will not be entered in the DAAS IMM field.

TBDSOR

Depot Source of Repair Codes (DSOR_0903)


Tobyhanna Army Depot (TYAD), PA

99DSOR

Depot Source of Repair Codes (DSOR_0903)


Depot source of repair has not been assigned. This is a temporary code that will be used only until a DSOR is assigned as specified in joint Service regulation AMC-R 750û10, OPNAVINST 4790.14A AFI 21û133(I), MCO P4790.10B, DLAD 4151.16, Joint Depot Maintenance Program, 31 March 1999.

GG

Supplementary Receivers (SUPPLM_RCVR_2534)


Naval Inventory Control Point, Philadelphia, PA 19111û5098


FLIS - SEG C - REFERENCE NUMBER | NSN 6130-01-164-0547 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
395CL30396770-1  24672  
524CLPP-7922/GSQ-215  80058   CAGE/80058
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

CL

Reference Number Action Activity Code (RNAAC_2900)


U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.


FLIS - SEG G - FREIGHT DATA | NSN 6130-01-164-0547 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
CLW658Z9AHZW062920Z35120REGULATORS-INDUCTION-VOLTAGE1
Code Definitions

CL

Originating Activity Code (ORIG_ACTY_CD_4210)


U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006

W

Less Than Carload (LCL_CD_2760)


Rating Variable

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

062920

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35120

Uniform Freight Classification (UFC_CD_MODF_3040)

REGULATORS-INDUCTION-VOLTAGE

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG H - MANAGEMENT DATA | NSN 6130-01-164-0547 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DAB16YY1DEA0
DNNRPXY1HEA0
Code Definitions

B16

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


US Army Communications-Electronics, Command and Fort Monmout, Fort Monmouth, NJ 07703-5016

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

Y

Controlled Item Inventory Code (CIIC_2863)


Communication/electronic equipment and parts

1

Quantity Unit Pack (QUP_6106)


1

D

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: When repair is beyond lower level maintenance capability, evacuate the item to depot. Disposal is not authorized below wholesale level; MARINE CORPS: Reparable item. When beyond lower level repair capability, return to depot. Condemnation and disposal not authorized below depot level; NAVY: Field Level Reparables

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

NRP

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


NAVICP-ERP, 700 Robbins Avenue, Philadelphia, PA 19111-5098

X

Acquisition Advice Code (AAC_2507)


SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.

H

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: If condemned or uneconomically repairable, then dispose at intermediate level; COAST GUARD: Reparable item. Repair, condemnation, and disposal not authorized below intermediate (district) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at fourth echelon level; NAVY: Depot Level Reparable

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6130-01-164-0547 Submit RFQ
MRCDecoded RequirementClear Text Reply
ABKWOverall Height5.250 INCHES NOMINAL
ABMKOverall Width19.000 INCHES NOMINAL
FEATSpecial FeaturesPWR.OUTPUT DATA:24VOLTS PLUS OR M INUS .5VDC;REGULATED;20AMP HRS.STDBY CAPACITY;ALARM INDIC:FUSE FAIL;AC INTR PT;AC PWR;HIGH CHARGE;BATTERY:24VDC;20 AMP.HR;RECHBL;SEALED;NO MAINTNCE;OPR PWR.RQMTS:AC;115V OR 230V PLUS OR MINUS 10%;WGT:55 LBS;MOUNTING DATA: RACK MOUNTED;DESIGNED FOR FIXED INSTALLATION; PROVIDES EMERGENCY PWR TO THE FREQUENCY CONTROL SET AN/GSQ IN EVENT OF PRIMARY PWR FAILURE


Back to Top
Back to Top