Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
9002-15 | 3 - Design Control Reference | 9 - No Longer Used | VEECO INSTRUMENTS INC | 80103 | ![]() |
146790-101 | 7 - Vendor Item Drawing Reference | 2 - Production Item | HARRIS CORPORATION | 91417 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6130 | 011712911 | A39900 | 00740 | H | K | B | N | A | 4 Feb 1984 |
Electric Wire, and Power and Distribution Equipment
The item is specifically designed to be or selected as being nuclear hard (i.e., it will continue to perform its designed function in an environment created by a nuclear explosion). The item does not have other critical features.
Full Descriptive - Reference Item Identification
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FUGG | FUCX | 3 | Z | Z | SU | 1 Feb 2005 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Ogden Air Logistics Center, Hill AFB, UT 84056-5609
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 4 Feb 1984 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TA | 595 | Z | 9 | A | H | Z | M | 062900 | X | 35110 | RECTIFIERS-NOI-BATTERY-ELIMINATORS |
Sacramento Air Logistics Center, McClellan AFB, CA 95652-5609
Transformer, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
85
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AJJY | Document Source | 80103 |
AKWC | Electrical Power Source Relationship | OPERATING |
AGAV | End Item Identification | MGT |
ADZC | Environmental Protection | FUNGUS PROOF |
CBBL | Features Provided | OVER TEMPERATURE PROTECTION AND OVER VOLTAGE PROTECTOR AND REMOTE ERROR SENSING CAPABILITY AND OUTPUT TO CASE ISOLATION |
AKAE | Maximum Operating Altitude Rating | 8000.0 FEET |
NHCF | Nuclear Hardness Critical Feature | HARDENED |
AYNH | Operating Ambient Temp Range | -0.1/+40.0 DEG CELSIUS |
CWHF | Output Connection Quantity | 2 SINGLE POWER OUTPUT |
CWHJ | Output Connection Type | SCREW SINGLE POWER OUTPUT |
CWGH | Output Current Rating | 5.5 DC AMPERES NOMINAL SINGLE POWER OUTPUT |
APPA | Output Voltage Rating | 15.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT |
CWHT | Input Connection Quantity | 2 SINGLE OPERATING POWER RQMT |
CWHQ | Input Connection Type | SCREW SINGLE OPERATING POWER RQMT |
APNX | Input Voltage Rating | 105.0 AC POUNDS PER HOUR DRY SINGLE OPERATING POWER RQMT AND 127.0 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE OPERATING POWER RQMT |
APTQ | Input Frequency Rating | 57.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
ANPM | Input Phase | SINGLE SINGLE OPERATING POWER RQMT |
CWGZ | Ripple Voltage At Full Load | 1.5 MILLIVOLTS RMS SINGLE POWER OUTPUT |
ABKW | Overall Height | 2.875 INCHES NOMINAL |
ABHP | Overall Length | 7.000 INCHES NOMINAL |
ABMK | Overall Width | 4.875 INCHES NOMINAL |
CWKG | Ventilation Design Type | CONVECTION |