Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
LND-X-152-7258-1 | 3 - Design Control Reference | 9 - No Longer Used | VEECO INSTRUMENTS INC | 80103 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6130 | 012008205 | A39900 | 00740 | X | 1 | A | N | A | 9 Feb 1985 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZH01 | 1 Jun 1996 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 9 | E | CX | LND-X-152-7258-1 | 80103 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Richmond, Richmond, VA 23297-5000
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 9 Feb 1985 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CH |
Defense Supply Center Richmond, Richmond, VA 23297
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AKWC | Electrical Power Source Relationship | OPERATING |
CBBL | Features Provided | FILTER |
AYNH | Operating Ambient Temp Range | +0.1/+71.0 DEG CELSIUS |
CWGH | Output Current Rating | 1.0 DC AMPERES MINIMUM 1ST POWER OUTPUT AND 2.5 DC AMPERES MAXIMUM 1ST POWER OUTPUT |
CWGH | Output Current Rating | 1.0 DC AMPERES MINIMUM 2ND POWER OUTPUT AND 2.5 DC AMPERES MAXIMUM 2ND POWER OUTPUT |
CWHF | Output Connection Quantity | 2 2ND POWER OUTPUT |
CWHF | Output Connection Quantity | 2 1ST POWER OUTPUT |
CWHJ | Output Connection Type | TERMINAL STRIP 1ST POWER OUTPUT |
CWHJ | Output Connection Type | TERMINAL STRIP 2ND POWER OUTPUT |
CWHC | Output Control Location | FRONT PANEL 2ND POWER OUTPUT |
CWHC | Output Control Location | FRONT PANEL 1ST POWER OUTPUT |
BGHX | Output Control Quantity | 1 1ST POWER OUTPUT |
BGHX | Output Control Quantity | 1 2ND POWER OUTPUT |
BGHY | Output Control Type | VOLTAGE ADJUSTMENT 1ST POWER OUTPUT |
BGHY | Output Control Type | VOLTAGE ADJUSTMENT 2ND POWER OUTPUT |
APPA | Output Voltage Rating | 15.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
APPA | Output Voltage Rating | -15.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
CWHT | Input Connection Quantity | 4 1ST OPERATING POWER RQMT |
CWHT | Input Connection Quantity | 4 2ND OPERATING POWER RQMT |
CWHQ | Input Connection Type | TERMINAL STRIP 1ST OPERATING POWER RQMT |
CWHQ | Input Connection Type | TERMINAL STRIP 2ND OPERATING POWER RQMT |
APNX | Input Voltage Rating | 105.0 AC VOLTS MINIMUM 2ND OPERATING POWER RQMT AND 127.0 AC VOLTS MAXIMUM 2ND OPERATING POWER RQMT |
APTQ | Input Frequency Rating | 47.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT |
APTQ | Input Frequency Rating | 47.0 HERTZ MINIMUM 2ND OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT |
ANPM | Input Phase | SINGLE 1ST OPERATING POWER RQMT |
ANPM | Input Phase | SINGLE 2ND OPERATING POWER RQMT |
APNX | Input Voltage Rating | 210.0 AC VOLTS MINIMUM 1ST OPERATING POWER RQMT AND 254.0 AC VOLTS MAXIMUM 1ST OPERATING POWER RQMT |
BHQN | Rectification Method | SINGLE PHASE FULL WAVE CENTER TAP |
ABKW | Overall Height | 2.875 INCHES NOMINAL |
ABHP | Overall Length | 7.000 INCHES NOMINAL |
ABMK | Overall Width | 4.875 INCHES NOMINAL |