Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
VB12G300 | 3 - Design Control Reference | 2 - Production Item | ACOPIAN TECHNICAL COMPANY | 14749 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6130 | 012378532 | A39900 | 00740 | X | K | A | N | A | 0 | 7 Aug 1986 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DGX1 | DCX1 | 3 | C | CX | 1 Sep 2006 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.
Defense Supply Center Richmond, Richmond, VA 23297-5000
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | D | SJ | VB12G300 | 14749 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by an engineering drawing. The drawing is available for limited use under the terms of the rights-in-data clause of the contract by which the data was obtained, and under the security measures specified for the level of security classification assigned. The drawing will be furnished only to qualified requesters by the activity identified by the RNAAC. Descriptive data based on Limited Rights information will not be released to the general public through publications or other media.
Air Force Cryptological Support Center, San Antonio, TX 78243-5000
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 7 Aug 1986 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SJ | 658 | Z | Z | A | H | Z | M | 062900 | X | 35110 | RECTIFIERS-NOI-BATTERY-ELIMINATORS |
Air Force Cryptological Support Center, San Antonio, TX 78243-5000
Electical Appliances, Small
No special type of cargo code applicable
No special handling required. Heavy Lift (HL). Five short tons (10,000 lbs) or more. Applies to any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN). Outsized Dimensions. Dimensions of any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN, CONEXs, and POVs) which exceed six (6) feet in any dimension.
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
85
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
APPA | Output Voltage Rating | 12.0 AC VOLTS NOMINAL SINGLE POWER OUTPUT |
CWGH | Output Current Rating | 2.5 AC AMPERES MINIMUM AND |
CWGH | Output Current Rating | 3.0 AC AMPERES MAXIMUM SINGLE POWER OUTPUT |
CWGN | Output Phase | SINGLE SINGLE POWER OUTPUT |
AGAV | End Item Identification | MNV;A116;AM7313/GFR DIST UNIT;DELIVERY |
SR-5 | Design Control Reference Or Manufacturers Code | |
SR-5 | Design Control Reference Or Manufacturers Code | 14749 |
SR-5 | Design Control Reference Or Manufacturers Code | VB12G300 |
APTQ | Input Frequency Rating | 50.0 HERTZ MINIMUM AND |
APTQ | Input Frequency Rating | 400.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
ANPM | Input Phase | SINGLE SINGLE OPERATING POWER RQMT |
CWKG | Ventilation Design Type | CONVECTION |
ABHP | Overall Length | 5.120 INCHES MAXIMUM |
ABMK | Overall Width | 3.440 INCHES MAXIMUM |
AMQY | Installation Design | RACK |
AYNH | Operating Ambient Temp Range | 0.1 TO 71.0 DEG CELSIUS |
CBBL | Features Provided | OVER VOLTAGE PROTECTOR AND |
CBBL | Features Provided | FUSE |
APTS | Output Frequency Rating | 40.0 HERTZ MINIMUM AND |
APTS | Output Frequency Rating | 400.0 HERTZ MAXIMUM SINGLE POWER OUTPUT |
ANRQ | Frequency Regulation Percent | 0.1 SINGLE POWER OUTPUT |
CWGZ | Ripple Voltage At Full Load | 1.5 MICROVOLTS RMS SINGLE POWER OUTPUT |
BGHY | Output Control Type | VOLTAGE ADJUSTMENT AND |
BGHY | Output Control Type | POLARITY POSITIVE-NEGATIVE SWITCH SINGLE POWER OUTPUT |
CWHF | Output Connection Quantity | 5 SINGLE POWER OUTPUT |
CWHJ | Output Connection Type | TERMINAL STRIP SINGLE POWER OUTPUT |
AKWC | Electrical Power Source Relationship | OPERATING |
APNX | Input Voltage Rating | 105.0 AC VOLTS MINIMUM AND |